The use of the McKeever metallic hemiarthroplasty for unicompartmental arthritis
- PMID: 3968111
The use of the McKeever metallic hemiarthroplasty for unicompartmental arthritis
Abstract
We reviewed the results of sixty-one McKeever unicompartmental arthroplasties performed by the senior one of us (T. P.) for osteoarthritis of the knee. The average follow-up was five years (range, two to thirteen years). Forty-four (72 per cent) of the arthroplasties were rated as good to excellent. The average postoperative range of motion in these knees was 110 degrees. Six knees were rated as fair and eleven knees, as poor. The poor results appeared to be caused by degenerative arthritis involving ipsilateral compartments that had not been resurfaced with an implant.