Performance of the Edwards Sapien 3 bioprosthesis in atrioventricular valve position: a case series

Affiliations
Case Reports

Performance of the Edwards Sapien 3 bioprosthesis in atrioventricular valve position: a case series

Alejandra Garretano et al. Eur Heart J Case Rep. .

Abstract

Background: The Edwards Sapien percutaneous valve (Edwards Lifesciences, Irvine, CA, USA) is a promising therapeutic option for congenital atrioventricular disease mostly because of the possibility to accommodate somatic growth with balloon dilatation.

Case summary: This article reports the performance of the Edwards Sapien 3 valve in atrioventricular valve position in four paediatric patients.

Discussion: Despite aggressive antiplatelet and anticoagulation strategies, most patients showed early bioprosthesis dysfunction, with increasing gradient not related with somatic growth. The decrease in leaflet motility in the absence of thrombosis or pannus could be associated with the low-velocity flow and low-pressure gradient that exists between the atria and ventricles in small children. It is well-known graft lifespan is usually shorter in small children, but we hypothesize the possibility of a second factor that valve design is intended to support higher flow-velocity patterns and can present an early failure in low-flow low-pressure situation. More studies are necessary to provide reliable evidence.

Keywords: Case report; Congenital heart disease; Mitral valve; Sapien 3; Tricuspid valve.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: None declared.

Figures

Figure 1
Figure 1
Evolutive functional changes in tricuspid valve (Case 2). (A) Transthoracic echocardiogram showing severe tricuspid regurgitation pre-surgery. (B1, B2) Transthoracic echocardiogram immediately after implant of the bioprosthesis. (C) Transthoracic echocardiogram 30 months after the implant with severe tricuspid regurgitation.

References

    1. Boone RH, Webb JG, Horlick E, Benson L, Cao QL, Nadeem N, et al. . Transcatheter pulmonary valve implantation using the Edwards SAPIEN™ transcatheter heart valve. Catheter Cardiovasc Interv 2010;75:286–294. - PubMed
    1. Kahl BS, Michel-Behnke I, Zimpfer D. Double atrioventricular valve replacement using Melody™ transcatheter valves in an infant with unbalanced atrioventricular septal defect: a case report. Eur Heart J Case Rep 2020;4:1–6. - PMC - PubMed
    1. Kenny D, Rhodes JF, Fleming GA, Kar S, Zahn EM, Vincent J, et al. . 3-year outcomes of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position from the COMPASSION multicenter clinical trial. JACC Cardiovasc Interv 2018;11:1920–1929. - PubMed
    1. Abdullah I, Ramirez FB, McElhinney DB, Lock JE, Del Nido PJ, Emani S. Modification of a stented bovine jugular vein conduit (melody valve) for surgical mitral valve replacement. Ann Thorac Surg 2012;94:e97–e98. - PubMed
    1. Quiñonez LG, Breitbart R, Tworetsky W, Lock JE, Marshall AC, Emani SM. Stented bovine jugular vein graft (Melody valve) for surgical mitral valve replacement in infants and children. J Thorac Cardiovasc Surg 2014;148:1443–1449. - PubMed