Diagnostic Utility of Cord Thyroid-Stimulating Hormone (TSH) in Congenital Hypothyroidism and Its Association With Perinatal Factors: A Study From a Tertiary Referral Centre in Hyderabad, India
- PMID: 39697936
- PMCID: PMC11653096
- DOI: 10.7759/cureus.73887
Diagnostic Utility of Cord Thyroid-Stimulating Hormone (TSH) in Congenital Hypothyroidism and Its Association With Perinatal Factors: A Study From a Tertiary Referral Centre in Hyderabad, India
Abstract
Introduction Congenital hypothyroidism (CH) is one of the most common, easily treatable, causes of long-term neurodevelopmental complications in children. The prevalence of CH in India is much higher compared to other countries. Although developed countries have well-established neonatal screening programs, a uniform nationwide screening program at birth is still not established in India. Cord blood thyroid-stimulating hormone (TSH) screening is crucial in diagnosing congenital hypothyroidism even with advancements in expanded newborn screening programs. The aim of this study was to determine the prevalence of elevated cord blood TSH levels and factors associated with it among newborns and to analyze the false positive rates of elevated cord blood TSH levels among the study population and factors associated with it. Methods This retrospective cross-sectional study was conducted among 51,251 live newborn babies born at Fernandez Hospital, Hyderabad, India, over a period of five years from January 2019 to December 2023. The data of all the mothers and newborns was retrieved from medical records and details of maternal age, parity, co-morbidities, mode of delivery, gestational age of the newborn at delivery, gender, number of babies, APGAR score, and birth weight were obtained. As per hospital policy, 5 ml of cord blood sample of all newborn babies was collected from the umbilical cord at the time of birth. Samples were analysed for cord TSH batchwise by the enzyme-linked immunosorbent assay (ELISA) method. As per the manufacturer, the normal biological reference intervals are <20 uIU/mL. All the cord TSH values > 20 uIU/ mL were considered abnormal and advised a repeat serum TSH test within 14 days of life. Cord TSH values that were higher than the biological reference range after retesting were considered positive for CH. All the initial and repeat results were retrieved from the neonatal digital database. Results Out of 51,251 live newborn babies, 71 (0.14%) were confirmed with a diagnosis of congenital hypothyroidism. The prevalence of CH in our study population was 1.4 per 1000 live births. Anaemia was found to be a statistically significant predictor of true positive cases (p<0.05). In our study, while evaluating risk factors for elevated cord TSH levels, we found that the babies born by vaginal delivery had higher cord TSH levels than babies born by lower segment caesarean section (LSCS) (p<0.001). The other variables considered in the study which include maternal age, BMI, parity of mother, gender of the baby, birth weight, gestation age and APGAR score were not statistically significant for CH. Conclusion The prevalence of congenital hypothyroidism was 1.4 in 1000 in our study. Mode of delivery and maternal anaemia had an impact on elevated cord TSH levels. These factors should be considered while interpreting cord TSH values. Cord TSH testing is an effective screening tool for CH. It helps in the early detection of thyroid dysfunction in newborns, enabling timely intervention and treatment to prevent developmental delays and other complications. This study presents evidence supporting the inclusion of cord blood TSH as a predictive factor in CH screening programs.
Keywords: congenital hypothyroidism; cord tsh; newborns; thyroid; universal screening.
Copyright © 2024, Fariduddin et al.
Conflict of interest statement
Human subjects: Consent for treatment and open access publication was obtained or waived by all participants in this study. Fernandez Foundation issued approval 38-2023. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work.
Figures



Similar articles
-
Screening for congenital hypothyroidism by using cord blood thyroid stimulating hormone (CBTSH) levels in neonates.J Family Med Prim Care. 2025 Apr;14(4):1375-1378. doi: 10.4103/jfmpc.jfmpc_1393_24. Epub 2025 Apr 25. J Family Med Prim Care. 2025. PMID: 40396058 Free PMC article.
-
Prevalence of Congenital Hypothyroidism and Efficacy of Current Cord Sample Screening in the Presence of Metabolic Screening: A Retrospective Cohort Study.Cureus. 2025 Feb 17;17(2):e79185. doi: 10.7759/cureus.79185. eCollection 2025 Feb. Cureus. 2025. PMID: 40115703 Free PMC article.
-
Cord blood versus heel-stick sampling for measuring thyroid stimulating hormone for newborn screening of congenital hypothyroidism.Ann Saudi Med. 2019 Sep-Oct;39(5):291-294. doi: 10.5144/0256-4947.2019.291. Epub 2019 Oct 3. Ann Saudi Med. 2019. PMID: 31580694 Free PMC article.
-
Newborn screening for congenital hypothyroidism.J Clin Res Pediatr Endocrinol. 2013;5 Suppl 1(Suppl 1):8-12. doi: 10.4274/jcrpe.845. Epub 2012 Nov 15. J Clin Res Pediatr Endocrinol. 2013. PMID: 23154158 Free PMC article. Review.
-
Congenital Hypothyroidism in Preterm Newborns - The Challenges of Diagnostics and Treatment: A Review.Front Endocrinol (Lausanne). 2022 Mar 18;13:860862. doi: 10.3389/fendo.2022.860862. eCollection 2022. Front Endocrinol (Lausanne). 2022. PMID: 35370986 Free PMC article. Review.
References
-
- Association of cord blood thyroid-stimulating hormone levels with maternal, delivery and infant factors. Tan KM, Chu AH, Loy SL, et al. Ann Acad Med Singap. 2020;49:937–947. - PubMed
-
- Congenital hypothyroidism. Brady J, Cannupp A, Myers J, Jnah AJ. Neonatal Netw. 2021;40:377–385. - PubMed
-
- Congenital hypothyroidism: current perspectives. Dayal D, Prasad R. RRED. 2015;5:91–102.
LinkOut - more resources
Full Text Sources
Research Materials