Mycobiology of Dental Unit Water: A Systematic Scoping Review
- PMID: 39701921
- PMCID: PMC11806301
- DOI: 10.1016/j.identj.2024.10.020
Mycobiology of Dental Unit Water: A Systematic Scoping Review
Abstract
Fungi present in Dental Unit Water (DUW) can pose a health hazard to patients and dental personnel. Yet, the issue of fungal contamination of DUW and their conduits, DUW Lines (DUWLs) has been poorly addressed despite a growing body of data on the subject. In this comprehensive review, we aim to address this gap by examining the diverse fungal contaminants found in DUW, the challenges associated with controlling their growth within waterline biofilms, and the various measures employed for fungal decontamination. The review underscores the intricate fungal ecosystems that exist within DUWLs and emphasizes the importance of implementing targeted antimicrobial strategies to uphold waterline hygiene. However, it is important to note that complete eradication of fungi in DUWLs has proven elusive, even with the application of disinfectants at varying concentrations, types, and frequencies. This highlights the pressing need for continued research efforts to develop new and optimized treatment protocols that are specifically tailored to eradicate fungi from DUWLs. Finally, it was notable that there are currently no specific regulations by any dental authority on permissible levels of fungi, as opposed to bacteria, in DUWLs. Legislation developed based on our findings can contribute to the standardization of practices and the formulation of effective control strategies for fungal contamination in DUWLs. It can also guide dental professionals in implementing regular monitoring, proper maintenance, and targeted disinfection protocols to minimize fungal contamination and ensure optimal water quality for patient safety.
Keywords: Antimicrobial; Biofilms; Dental Unit Water Lines (DUWLs); Mold; Yeasts.
Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.
Conflict of interest statement
Conflict of interest The author(s) below of the captioned paper have declared no potential conflicts of interest.
Figures
Similar articles
-
Waterline biofilm and the dental treatment facility: a review.Gen Dent. 2002 Mar-Apr;50(2):190-5; quiz 196-7. Gen Dent. 2002. PMID: 12004714 Review.
-
Dental Unit Waterlines: Disinfection and Management.Int Dent J. 2024 Nov;74 Suppl 2(Suppl 2):S437-S445. doi: 10.1016/j.identj.2024.07.1269. Int Dent J. 2024. PMID: 39515931 Free PMC article. Review.
-
Efficacy of acoustic waves in preventing Streptococcus mutans adhesion on dental unit water line.Ann Ig. 2019 Mar-Apr;31(2):109-116. doi: 10.7416/ai.2019.2263. Ann Ig. 2019. PMID: 30714608
-
Bacterial contamination of new dental unit waterlines and efficacy of shock disinfection.BMC Microbiol. 2024 Dec 19;24(1):529. doi: 10.1186/s12866-024-03678-7. BMC Microbiol. 2024. PMID: 39695925 Free PMC article.
-
Disinfection methods of dental unit waterlines contamination: a systematic review.J Med Microbiol. 2022 Jun;71(6). doi: 10.1099/jmm.0.001540. J Med Microbiol. 2022. PMID: 35670283
Cited by
-
Extra Positive Air Pressure to Prevent Microbial Contamination in Dental Handpieces: An Experimental Study.Int Dent J. 2025 Aug 4;75(5):100917. doi: 10.1016/j.identj.2025.100917. Online ahead of print. Int Dent J. 2025. PMID: 40763687 Free PMC article.
References
-
- Walker J.T., Marsh P.D. Microbial biofilm formation in DUWS and their control using disinfectants. J Dent. 2007;35(9):721–730. - PubMed
-
- Marino F., Mazzotta M., Pascale M.R., Derelitto C., Girolamini L., Cristino S. First water safety plan approach applied to a Dental Clinic complex: identification of new risk factors associated with Legionella and P. aeruginosa contamination, using a novel sampling, maintenance and management program. J Oral Microbiol. 2023;15(1):2223477. - PMC - PubMed
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous