Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Dec 26;34(1):1-10.

[Evaluation of Quick Chaser CD GDH/TOX, a Rapid Diagnostic Kit for Simultaneous Detection of Clostridioides difficile Antigen and Toxin A/B, in Fecal Specimens]

[Article in Japanese]
Affiliations
  • PMID: 39716377

[Evaluation of Quick Chaser CD GDH/TOX, a Rapid Diagnostic Kit for Simultaneous Detection of Clostridioides difficile Antigen and Toxin A/B, in Fecal Specimens]

[Article in Japanese]
Nohara Tsukamoto et al. Rinsho Biseibutshu Jinsoku Shindan Kenkyukai Shi. .

Abstract

For Clostridioides difficile infections, highly sensitive rapid diagnostic test kits are necessary for prompt diagnose and infection control. In this study, we evaluated "Quick Chaser CD GDH/TOX" (evaluation kit), a rapid diagnostic kit for C. difficile, using 65 clinical stool specimens, comparing with GE test immunochromato-CD GDH/TOX "Nissui" (GE test) and TECHLAB C. DIFF QUIK CHEK COMPLETE (QUIK CHEK). The results of the evaluation kit showed a high concordance rate; 100% the positive concordance rate (31/31) and 97.1% the negative concordance rate (33/34) of GDH, 94.1% the positive concordance rate (16/17) and 97.9% the negative concordance rate (47/48) of toxin against GE test, respectively. Also 96.9% the positive concordance rate (31/32) and 97.0% the negative concordance rate (32/33) of GDH, 100% the positive concordance rate (12/12) and 90.6% the negative concordance rate (48/53) of toxin against QUIK CHEK, respectively. Additionally, comparison of discrepancy cases between kits based on Nucleic Acid Amplification test, one false negative each for GDH and toxin in the evaluation kit, two false negatives for GDH and one false negative for toxin in the GE test, one false negative for GDH and six false negatives for toxin in QUIK CHEK, and no false positive cases were observed. Therefore, the detection sensitivity of GDH and toxin of the evaluation kit was equivalent to that of two types of comparative kits.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources