Differential effects of stimulation waveform and intensity on the neural structures activated by lumbar transcutaneous spinal cord stimulation
- PMID: 39718492
- DOI: 10.1152/jn.00266.2024
Differential effects of stimulation waveform and intensity on the neural structures activated by lumbar transcutaneous spinal cord stimulation
Abstract
Lumbar transcutaneous spinal cord stimulation (TSS) evokes synchronized muscle responses, termed spinally evoked motor response (sEMR). Whether the structures TSS activates to evoke sEMRs differ when TSS intensity and waveform are varied is unknown. In 15 participants (9 F, 6 M), sEMRs were evoked by TSS over L1-L3 (at sEMR threshold and suprathreshold intensities) with conventional (one 400-µs biphasic pulse) or high-frequency burst (ten 40-µs biphasic pulses at 10 kHz) stimulus waveforms in vastus medialis (VM), tibialis anterior (TA), and medial gastrocnemius (MG) muscles. TSS was paired with transcranial magnetic stimulation (TMS) over the contralateral motor cortex at relative interstimulus intervals (ISIs) (-10 ms to 11 ms), centered on the ISI when TSS and TMS inputs simultaneously activated VM motoneurons. Doublet TSS was delivered at 80-ms ISI. For VM, the area of the combined response evoked by paired TMS and TSS was not facilitated at any ISI. For TA and MG, combined responses were facilitated by ∼40-100% when TMS activated the motoneurons before or at a similar time as TSS, particularly with suprathreshold TSS. Additionally, for TA, there was greater suppression of the second sEMR evoked by TSS doublets using suprathreshold conventional TSS compared to high-frequency burst TSS (P < 0.001). The results suggest that for VM TSS activated predominantly motor axons, but for TA and MG facilitation of the sEMR by TMS suggests that TSS activated sensory axons. Stimulation waveforms had similar outcomes in most conditions.NEW & NOTEWORTHY Transcutaneous spinal cord stimulation (TSS) can evoke muscle responses by activation of sensory and/or motor axons. The relative contribution of these varies across the muscles tested. We found evidence for activation of sensory axons with TSS for tibialis anterior and medial gastrocnemius but not for vastus medialis. In cases where sensory axons were activated, conventional TSS activated relatively more sensory axons than high-frequency burst TSS.
Keywords: carrier frequency; conventional stimulation; high-frequency carrier stimulation; posterior root muscle reflex; transcutaneous spinal cord stimulation.
Copyright © 2025 The Authors.
Similar articles
-
Preferential activation of spinal sensorimotor networks via lateralized transcutaneous spinal stimulation in neurologically intact humans.J Neurophysiol. 2019 Nov 1;122(5):2111-2118. doi: 10.1152/jn.00454.2019. Epub 2019 Sep 25. J Neurophysiol. 2019. PMID: 31553681
-
Transcutaneous spinal stimulation in people with and without spinal cord injury: Effect of electrode placement and trains of stimulation on threshold intensity.Physiol Rep. 2023 Jun;11(11):e15692. doi: 10.14814/phy2.15692. Physiol Rep. 2023. PMID: 37269156 Free PMC article.
-
Distinguishing reflex from non-reflex responses elicited by transcutaneous spinal stimulation targeting the lumbosacral cord in healthy individuals.Exp Brain Res. 2024 Apr;242(4):959-970. doi: 10.1007/s00221-024-06790-2. Epub 2024 Feb 28. Exp Brain Res. 2024. PMID: 38416179 Free PMC article.
-
Convergence of flexor reflex and corticospinal inputs on tibialis anterior network in humans.Clin Neurophysiol. 2016 Jan;127(1):706-715. doi: 10.1016/j.clinph.2015.06.011. Epub 2015 Jun 18. Clin Neurophysiol. 2016. PMID: 26122072
-
Electrical stimulation of human corticospinal axons at the level of the lumbar spinal segments.Eur J Neurosci. 2019 May;49(10):1254-1267. doi: 10.1111/ejn.14321. Epub 2019 Jan 16. Eur J Neurosci. 2019. PMID: 30589956
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources