Performance investigation of MVMD-MSI algorithm in frequency recognition for SSVEP-based brain-computer interface and its application in robotic arm control
- PMID: 39725763
- DOI: 10.1007/s11517-024-03236-3
Performance investigation of MVMD-MSI algorithm in frequency recognition for SSVEP-based brain-computer interface and its application in robotic arm control
Abstract
This study focuses on improving the performance of steady-state visual evoked potential (SSVEP) in brain-computer interfaces (BCIs) for robotic control systems. The challenge lies in effectively reducing the impact of artifacts on raw data to enhance the performance both in quality and reliability. The proposed MVMD-MSI algorithm combines the advantages of multivariate variational mode decomposition (MVMD) and multivariate synchronization index (MSI). Compared to widely used algorithms, the novelty of this method is its capability of decomposing nonlinear and non-stationary EEG signals into intrinsic mode functions (IMF) across different frequency bands with the best center frequency and bandwidth. Therefore, SSVEP decoding performance can be improved by this method, and the effectiveness of MVMD-MSI is evaluated by the robot with 6 degrees-of-freedom. Offline experiments were conducted to optimize the algorithm's parameters, resulting in significant improvements. Additionally, the algorithm showed good performance even with fewer channels and shorter data lengths. In online experiments, the algorithm achieved an average accuracy of 98.31% at 1.8 s, confirming its feasibility and effectiveness for real-time SSVEP BCI-based robotic arm applications. The MVMD-MSI algorithm, as proposed, represents a significant advancement in SSVEP analysis for robotic control systems. It enhances decoding performance and shows promise for practical application in this field.
Keywords: Brain-computer interface; Multivariate synchronization index; Multivariate variational mode decomposition; Robotic arm; Steady-state visual evoked potential.
© 2024. International Federation for Medical and Biological Engineering.
Conflict of interest statement
Declarations. Ethical approval: All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Informed consent: Informed consent was obtained from all individual participants included in the study. Competing interests: The authors declare no competing interests.
References
-
- Värbu K, Muhammad N, Muhammad Y (2022) Past, present, and future of EEG-based BCI applications. Sensors 22(9):3331. https://doi.org/10.3390/s22093331 - DOI - PubMed - PMC
-
- Horki P, Solis-Escalante T, Neuper C, Müller-Putz G (2011) Combined motor imagery and SSVEP based BCI control of a 2 DoF artificial upper limb. Med Biol Eng Comput 49:567–577. https://doi.org/10.1007/s11517-011-0750-2 - DOI - PubMed
-
- Quiles E, Dadone J, Chio N et al (2022) Cross-platform implementation of an SSVEP-based BCI for the control of a 6-DOF robotic arm. Sensors 22(13):5000. https://doi.org/10.3390/s22135000 - DOI - PubMed - PMC
-
- Chen X, Zhao B, Wang Y et al (2018) Control of a 7-DOF robotic arm system with an SSVEP-based BCI. Int J Neural Syst 28(08):1850018. https://doi.org/10.1142/S0129065718500181 - DOI - PubMed
-
- Apicella A, Arpaia P, De Benedetto E et al (2022) Enhancement of SSVEPs classification in BCI-based wearable instrumentation through machine learning techniques. IEEE Sens J 22(9):9087–9094. https://doi.org/10.1109/JSEN.2022.3161743 - DOI
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources