Ultrasonic attenuation and velocity properties in rat liver as a function of fat concentration: a study at 100 MHz using a scanning laser acoustic microscope
- PMID: 3973224
- DOI: 10.1121/1.392229
Ultrasonic attenuation and velocity properties in rat liver as a function of fat concentration: a study at 100 MHz using a scanning laser acoustic microscope
Abstract
This study examines the extent to which ultrasonic attenuation coefficients and velocity properties change between normal and fatty rat liver. The view of this problem is toward the application in clinical medicine in the future. Fatty livers were produced in rats by feeding them alcohol diets in liquid form. The animals were sacrificed and the fat concentration of the liver specimens determined. The fat concentration varied from 2.5% to 16.8% wet weight. The ultrasonic attenuation coefficient and velocity properties in 28 specimens were measured at 100 MHz with the scanning laser acoustic microscope (SLAM). Regression analysis was applied to the liver's ultrasonic propagation properties as a function of fat concentration. The results show that the attenuation coefficient increases at a rate of 1.08 dB/mm/% fat and the velocity decreases at a rate of 2.3 m/s/% fat as the fat concentration increases.
Similar articles
-
Ultrasonic propagation properties (@ 100 MHz) in excessively fatty rat liver.J Acoust Soc Am. 1988 Mar;83(3):1159-66. doi: 10.1121/1.396060. J Acoust Soc Am. 1988. PMID: 3281985
-
Correlation of tissue constituents with the acoustic properties of skin and wound.Ultrasound Med Biol. 1990;16(1):55-64. doi: 10.1016/0301-5629(90)90086-r. Ultrasound Med Biol. 1990. PMID: 2321315
-
Measurement of the acoustic properties of a nerve-muscle preparation as a function of physiologic state.Ultrasonics. 1976 Nov;14(6):283-5. doi: 10.1016/0041-624x(76)90038-x. Ultrasonics. 1976. PMID: 996975
-
Correlation of ultrasonic attenuation with pathologic fat and fibrosis in liver disease.Ultrasound Med Biol. 1988;14(8):729-34. doi: 10.1016/0301-5629(88)90028-2. Ultrasound Med Biol. 1988. PMID: 3062866 Review.
-
[Acoustic microscope and its medical applications].Nihon Rinsho. 1995 Jun;53(6):1527-35. Nihon Rinsho. 1995. PMID: 7616673 Review. Japanese.
Cited by
-
Ultrasound attenuation in biological tissues using a bone transducer.Med Biol Eng Comput. 1987 Nov;25(6):689-92. doi: 10.1007/BF02447341. Med Biol Eng Comput. 1987. PMID: 3505310 No abstract available.
-
Exvivo ultrasound attenuation coefficient for human cervical and uterine tissue from 5 to 10 MHz.Ultrasonics. 2011 May;51(4):467-71. doi: 10.1016/j.ultras.2010.11.012. Epub 2010 Nov 27. Ultrasonics. 2011. PMID: 21163508 Free PMC article.
-
Ultrasonic characterization of porcine liver tissue at frequency between 25 to 55 MHz.World J Gastroenterol. 2006 Apr 14;12(14):2276-9. doi: 10.3748/wjg.v12.i14.2276. World J Gastroenterol. 2006. PMID: 16610036 Free PMC article.
-
The effects of frequency-dependent attenuation and dispersion on sound speed measurements: applications in human trabecular bone.IEEE Trans Ultrason Ferroelectr Freq Control. 2000;47(1):265-73. doi: 10.1109/58.818770. IEEE Trans Ultrason Ferroelectr Freq Control. 2000. PMID: 18238539 Free PMC article.
-
Local Sound Speed Estimation for Pulse-Echo Ultrasound in Layered Media.IEEE Trans Ultrason Ferroelectr Freq Control. 2022 Feb;69(2):500-511. doi: 10.1109/TUFFC.2021.3124479. Epub 2022 Jan 27. IEEE Trans Ultrason Ferroelectr Freq Control. 2022. PMID: 34723801 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous