Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2025 Jan 1;25(1):67-73.
doi: 10.4103/jips.jips_40_24. Epub 2025 Jan 3.

Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier abutment bridges: An in vitro study

Affiliations
Comparative Study

Comparison of marginal fit between milled and three-dimensional printed polymethylmethacrylate prostheses for single crowns, anterior bridges, and pier abutment bridges: An in vitro study

Aman Merchant et al. J Indian Prosthodont Soc. .

Abstract

Aim: The purpose of this in vitro study was to compare the marginal fit of various three-dimensional (3D) printed and milled polymethylmethacrylate (PMMA) dental prostheses.

Settings and design: The study was conducted in an in vitro study setting.

Materials and methods: With a sample size of 45 for each fabrication method, this investigation compared the marginal fit of milled (Group 1) and 3D printed (Group 2) PMMA dental prostheses across different designs. The selection of samples was based on G*Power calculations. Tooth preparations were conducted on a typodont jaw set, followed by digital scanning and design processes. Computer-aided design and computer-aided manufacturing milling and 3D printing were employed for the fabrication of prostheses. The assessment of marginal accuracy at specific points was performed using a stereomicroscope.

Statistical analysis used: Independent t-tests were used to evaluate marginal discrepancies between milled and printed prosthetic designs at specific tooth surfaces. Univariate analysis of variance assessed marginal discrepancies across prosthesis designs and fabrication methods, with the Tukey post hoc test for significantly different results (α =0.05).

Results: Milled single crowns exhibited superior accuracy (61.50 ± 4.852 μ) compared to printed ones (65.74 ± 7.311 μ) (t = -1.868, P = 0.037). Similar trends were observed for other designs, emphasizing the impact of both prosthesis design and fabrication method on marginal fit. Notable discrepancies were found on the distal surfaces of the anterior bridge crossing midline design (t = -3.262, P = 0.003).

Conclusion: Milled prostheses exhibited superior marginal fit as compared to 3D printed prostheses, with differences within clinically acceptable limits.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

Figures

Figure 1
Figure 1
(1) Milled and (2) Three-dimensional printed (a) Anterior bridges spanning the midline, (b) Single crowns, and (c) Pier abutment bridges spanning from canine to second molar
Figure 2
Figure 2
(a and b) Evaluation of marginal discrepancy using a stereomicroscope, (c) at 100X magnification
Figure 3
Figure 3
Marginal discrepancies between milled and printed prosthetic designs for different prosthesis designs. CI: Confidence interval
Figure 4
Figure 4
Mean marginal discrepancy across each surface (a) Mesial, (b) Distal, (c) Buccal, (d) Lingual, recorded for different prosthetic designs when fabricated using milling and three-dimensional printing. CI: Confidence interval

References

    1. Rokaya D, Srimaneepong V, Sapkota J, Qin J, Siraleartmukul K, Siriwongrungson V. Polymeric materials and films in dentistry: An overview. J Adv Res. 2018;14:25–34. - PMC - PubMed
    1. Arora O, Ahmed N, Maiti S. Comparison of the marginal accuracy of metal copings fabricated by 3D-printed resin and milled polymethyl methacrylate - An in vitro study. J Adv Pharm Technol Res. 2022;13:S238–42. [doi: 10.4103/japtr.japtr_210_22] - PMC - PubMed
    1. Singh P, Maiti S, Shenoy A. Comparative evaluation of bond strength and color stability of polyetheretherketone and zirconia layered with indirect composite before and after thermocycling: An in vitro study. J Indian Prosthodont Soc. 2024;24:252–8. [doi: 10.4103/jips.jips_36_24] - PMC - PubMed
    1. Hassan M, Asghar M, Din SU, Muhammad SZ. Materials for Biomedical Engineering. Elsevier; 2019. Thermoset polymethacrylate-based materials for dental applications; pp. 273–308.
    1. Alam M, Chugh A, Kumar A, Rathee M, Jain P. Comparative evaluation of fracture resistance of anterior provisional restorations fabricated using conventional and digital techniques – An in vitro study. J Indian Prosthodont Soc. 2022;22:361–7. - PMC - PubMed

Publication types

Substances