RM Pressfit vitamys: the 10-year follow-up
- PMID: 39772936
- DOI: 10.1177/11207000241304659
RM Pressfit vitamys: the 10-year follow-up
Abstract
Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?
Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.4% in women. The mean age was 67.2 years (standard deviation [SD] 9.5), and the mean BMI was 27.3 kg/m2 (SD 4.7). In 153 cases (94.4%), primary or secondary osteoarthritis was the diagnosis. We evaluated preoperative and follow-up data at 6 weeks, 1, 5, and 10 years. A modified Harris Hip Score (mHHS), pain and satisfaction on a visual analogue scale (VAS), radiographic evaluation, complications and revision rate were investigated.
Results: At the 10-year follow-up (mean 120.5 months, SD 1.4, range 118-126), 99 hips were available for clinical and radiographic evaluation. (1) The mean mHHS was 94.8 (SD 9.9), rest pain 0.2 (SD 0.6), load pain 0.5 (SD 1.5), and satisfaction 9.5 (SD 1.1). The mean improvement as compared to preoperatively was +33.7 (SD 16.8), -3.3 (SD 2.7), -6.0 (SD 2.4) and +5.7 (SD 2.5), respectively. (2) In the radiographic evaluation, no loose cups, no acetabular lucent lines, or acetabular osteolysis were seen. (3) 2 cups were revised, both due to malpositioning. The 10-year cumulative revision rate was 2.0% (95%CI, 0.0-4.2%). The implant survival rate with aseptic loosening as endpoint was 100%. No adverse events were reported.
Conclusions: At the 10-year follow-up, the RM Pressfit vitamys cup still had promising results with good clinical and radiographic outcomes and a low revision rate.
Keywords: 10-year follow-up; Acetabular cup; RM Pressfit vitamys; highly cross-linked polyethylene (HXLPE); isoelastic uncemented monoblock cup; radiographic/clinical outcomes; revision rate; survival; total hip arthroplasty; vitamin E.
Conflict of interest statement
Declaration of conflicting interestsThe author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: MB: Scientific Consultant for Mathys (Bettlach, Switzerland).B-C L: Educational Consultant for Mathys (Bettlach, Switzerland).All other authors declare that there is no conflict of interest.
Similar articles
-
The RM Pressfit vitamys: 5-year Swiss experience of the first 100 cups.Hip Int. 2017 Jul 25;27(4):368-372. doi: 10.5301/hipint.5000469. Epub 2017 Jan 20. Hip Int. 2017. PMID: 28106229
-
A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.Acta Orthop. 2020 Dec;91(6):705-710. doi: 10.1080/17453674.2020.1807220. Epub 2020 Aug 24. Acta Orthop. 2020. PMID: 32835560 Free PMC article. Clinical Trial.
-
Results of third generation dual mobility total hip arthroplasties with non-cross-linked polyethylene in patients under 60 years of age: comparative study of full pressfit vs. tripod cups after 8.6 years.Orthop Traumatol Surg Res. 2024 Oct;110(6):103934. doi: 10.1016/j.otsr.2024.103934. Epub 2024 Jul 10. Orthop Traumatol Surg Res. 2024. PMID: 38991889
-
The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.BMC Musculoskelet Disord. 2021 Jan 23;22(1):107. doi: 10.1186/s12891-021-03981-8. BMC Musculoskelet Disord. 2021. PMID: 33485345 Free PMC article.
-
High wear rates and extensive osteolysis in 3 types of uncemented total hip arthroplasty: a review of the PCA, the Harris Galante and the Profile/Tri-Lock Plus arthroplasties with a minimum of 12 years median follow-up in 96 hips.Acta Orthop. 2006 Aug;77(4):575-84. doi: 10.1080/17453670610012638. Acta Orthop. 2006. PMID: 16929433 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical