. 2025 Mar;48(1):21-33.
doi: 10.1007/s13246-024-01486-x. Epub 2025 Jan 8.

In-silico evaluation of the effect of set-up errors on dose delivery during mouse irradiations with a Cs-137 cell irradiator-based collimator system

Affiliations

In-silico evaluation of the effect of set-up errors on dose delivery during mouse irradiations with a Cs-137 cell irradiator-based collimator system

Amir Entezam et al. Phys Eng Sci Med. 2025 Mar.

Abstract

Set-up errors are a problem for pre-clinical irradiators that lack imaging capabilities. The aim of this study was to investigate the impact of the potential set-up errors on the dose distribution for a mouse with a xenographic tumour irradiated with a standard Cs-137 cell irradiator equipped with an in-house lead collimator with 10 mm diameter apertures. The EGSnrc Monte-Carlo (MC) code was used to simulate the potential errors caused by displacements of the mouse in the irradiation setup. The impact of the simulated set-up displacements on the dose delivered to the xenographic tumour and surrounding organs was assessed. MC dose calculations were performed in a Computed Tomography (CT) derived model of the mouse for the reference position of the tumour in the irradiation setup. The errors were added into the CT data and then the mouse doses for the corresponding shifts were recalculated and dose volume histograms (DVHs) were generated. The investigation was performed for 1 cm and 0.5 cm diameter tumours. The DVH resulting from introducing the maximum setup errors for 1 cm diameter tumours showed up to 35% reduced dose to a significant fraction of the tumour volume. The setup errors demonstrated an insignificant effect on doses for 0.5 cm diameter tumour irradiations. Setup errors were observed to have negligible impact on out of field doses to organs at risk. The dosimetric results presented herein verify the robustness of our collimator system for irradiations of xenograft tumours up to 0.5 cm diameter in the presence of the maximum setup errors.

Keywords: Collimator; Monte carlo simulations; Mouse phantom; Setup errors; Small animal irradiation; Xenographic tumour model.

PubMed Disclaimer

Conflict of interest statement

Declarations. Ethical approval: This article does not contain any studies with human participants or animals performed by any of the authors. Competing interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

References

    1. Ford NL, Loudos GK, Karnabatidis DN, Kagadis GC (2018) Defining small animal imaging, therapy, and applications. In: Handbook of small animal imaging, CRC Press, p 3–5
    1. Milas L, Milas MM, Mason KA (1999) Combination of taxanes with radiation: preclinical studies. Semin Radiat Oncol 9(2 Suppl 1):12–26
    1. Bockel S, Durand B, Deutsch E (2018) Combining radiation therapy and cancer immune therapies: from preclinical findings to clinical applications. Cancer/Radiothérapie 22(6–7):567–580 - DOI - PubMed
    1. Wada S, Harris TJ, Tryggestad E, Yoshimura K, Zeng J, Yen HR, Drake CG (2013) Combined treatment effects of radiation and immunotherapy: studies in an autochthonous prostate cancer model. Int J Radiat Oncol Biol Phys 87(4):769–776 - DOI - PubMed - PMC
    1. Deng Z, Xu X, Garzon-Muvdi T, Xia Y, Kim E, Belcaid Z, Wang KKH (2020) Vivo Bioluminescence Tomography Center of Mass-guided conformal irradiation. Int J Radiat Oncol Biol Phys 106(3):612–620 - DOI - PubMed