Reliability of running gait variability measures calculated from inertial measurement units
- PMID: 39799726
- DOI: 10.1016/j.jbiomech.2025.112515
Reliability of running gait variability measures calculated from inertial measurement units
Abstract
Changes to the variability within biomechanical signals may reflect a change in the health of the human system. However, for running gait variability measures calculated from wearable device data, it is unknown whether a between-day difference reflects a shift in system dynamics reflective of a change in human health or is a result of poor between-day reliability of the measurement device or the biomechanical signal. This study investigated the reliability of stride time and sacral acceleration variability measures calculated from inertial measurement units (IMUs). Nineteen runners completed six treadmill running trials on two occasions seven days apart. Stride time and sacral acceleration signals were obtained using IMUs. Stride time variability and complexity were calculated using the coefficient of variation (CV) and detrended fluctuation analysis (DFA), respectively. Sacral acceleration regularity was quantified using sample entropy with a range of input parameters m (vector length) and r (similarity threshold). Between-day reliability was assessed using the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimum detectable change. Stride time CV displayed moderate relative reliability (ICC = 0.672), but with a large absolute minimum detectable change = 0.525 %, whilst stride time DFA-α displayed poor relative reliability (ICC = 0.457) and yielded large minimum detectable changes (≥ 0.208). Sample entropy displayed good relative reliability in mediolateral and resultant sacral acceleration signals for certain combinations of the parameters m and r, although again with large minimum detectable changes. Researchers should be cognisant of these reliability metrics when interpreting changes in running gait variability measures in clinical contexts.
Keywords: Between-day reliability; Complexity; Inertial measurement unit; Regularity; Running gait.
Copyright © 2025 The Authors. Published by Elsevier Ltd.. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
The repeatability of stride time variability, regularity, and long-range correlations.Gait Posture. 2024 Oct;114:257-262. doi: 10.1016/j.gaitpost.2024.10.014. Epub 2024 Oct 19. Gait Posture. 2024. PMID: 39427358
-
The one-week and three-month reliability of acceleration outcomes from an insole-embedded inertial measurement unit during treadmill running.Sports Biomech. 2025 May;24(5):1429-1443. doi: 10.1080/14763141.2023.2275258. Epub 2023 Nov 9. Sports Biomech. 2025. PMID: 37941419
-
Reliability of the fluctuations within the stride time series measured in runners during treadmill running to exhaustion.Gait Posture. 2019 Oct;74:1-6. doi: 10.1016/j.gaitpost.2019.08.008. Epub 2019 Aug 11. Gait Posture. 2019. PMID: 31434023
-
Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis.J Neuroeng Rehabil. 2020 May 11;17(1):62. doi: 10.1186/s12984-020-00685-3. J Neuroeng Rehabil. 2020. PMID: 32393301 Free PMC article.
-
Does Site Matter? Impact of Inertial Measurement Unit Placement on the Validity and Reliability of Stride Variables During Running: A Systematic Review and Meta-analysis.Sports Med. 2021 Jul;51(7):1449-1489. doi: 10.1007/s40279-021-01443-8. Epub 2021 Mar 24. Sports Med. 2021. PMID: 33761128
MeSH terms
LinkOut - more resources
Full Text Sources