Comparing analog and 3D measurements of vertical dimension in edentulous subjects

Affiliations
Free article
Comparative Study

Comparing analog and 3D measurements of vertical dimension in edentulous subjects

Murali Srinivasan et al. J Dent. 2025 Mar.
Free article

Abstract

Objective: This study aimed to explore the feasibility and reliability of measuring the vertical dimension of occlusion/rest (OVD/RVD) on 3D facial scans of edentulous patients.

Methods: Nineteen edentulous participants rehabilitated with complete removable dental prostheses (CDs) participated in this study. Analog measurements (control) were obtained directly on the face for each participant with the jaws positioned at the rest position (without CDs, RVD) and at centric occlusion (with dentures, OVD), between the facial landmarks: Glabella (G) and Soft Pogonion (SP), Pronasale (PN) and SP, and Subnasale (SN) and SP. Participants' faces were scanned twice, using a face-scanner (Class 1 LASER, Obiscanner). Scans were imported into a mesh-processing software, and the OVD/RVD were measured digitally. Two investigators performed all the measurements and were blinded. Data analysis included intra-class correlation coefficient (ICC) and pairwise comparison tests (p < 0.05).

Results: Digital measurements were higher than analog measurements, and the mean paired difference ranged from -4.86±3.2 to 0.42±2.7 mm. All the differences were statistically significant, expect for SN-SP (p = 0.110). Magnitude of the differences for the RVD were large for G-SP and SN-SP (ES>0.80) and moderate for PN-SP (ES>0.50). There was a large effect for G-SP when measuring OVD (ES>0.50), and small effect for PN-SP and SN-SP (ES≤0.20).

Conclusion: Considering the limitations associated with the specific type of facial scanner used in this study, it can be concluded that registering the resting vertical dimension in edentulous patients through digital methods may not be currently recommended. This is due to the potential errors that may arise during the data acquisition process, which could compromise the accuracy and reliability of the measurements.

Clinical significance: Digital methods for registering the vertical dimension of rest (RVD) in edentulous patients can introduce errors, resulting in occlusal errors and discomfort. Clinicians must, for the moment, still use conventional analog methods to ensure accurate RVD measurement for a successful denture therapy.

Keywords: Computer-aided design; Computer-aided manufacturing; Dentures, complete; Geriatric dentistry; Humans; Prosthodontics; Vertical dimension.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare that they have no conflict of interests.