Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Jul;94(1):302-316.
doi: 10.1002/mrm.30434. Epub 2025 Jan 17.

Relaxometry and contrast-free cerebral microvascular quantification using balanced steady-state free precession MR fingerprinting

Affiliations
Free article

Relaxometry and contrast-free cerebral microvascular quantification using balanced steady-state free precession MR fingerprinting

Thomas Coudert et al. Magn Reson Med. 2025 Jul.
Free article

Abstract

Purpose: This study proposes a novel, contrast-free Magnetic Resonance Fingerprinting (MRF) method using balanced Steady-State Free Precession (bSSFP) sequences for the quantification of cerebral blood volume (CBV), vessel radius (R), and relaxometry parameters (T 1 $$ {}_1 $$ , T 2 $$ {}_2 $$ , T 2 $$ {}_2 $$ *) in the brain.

Methods: The technique leverages the sensitivity of bSSFP sequences to intra-voxel frequency distributions in both transient and steady-state regimes. A dictionary-matching process is employed, using simulations of realistic mouse microvascular networks to generate the MRF dictionary. The method is validated through in silico and in vivo experiments on six healthy subjects, comparing results with standard MRF methods and literature values.

Results: The proposed method shows strong correlation and agreement with standard MRF methods for T 1 $$ {}_1 $$ and T 2 $$ {}_2 $$ values. High-resolution maps provide detailed visualizations of CBV and microvascular structures, highlighting differences in white matter (WM) and gray matter (GM) regions. The measured GM/WM ratio for CBV is 1.91, consistent with literature values.

Conclusion: This contrast-free bSSFP-based MRF method offers an new approach for quantifying CBV, vessel radius, and relaxometry parameters. Further validation against DSC imaging and clinical studies in pathological conditions is warranted to confirm its clinical utility.

Keywords: Cerebral Blood Volume (CBV); Magnetic Resonance Fingerprinting (MRF); Quantitative; Relaxometry; Vascularisation; balanced Steady‐State Free Precession (bSSFP).

PubMed Disclaimer

References

REFERENCES

    1. van Dijken BRJ, van Laar PJ, Holtman GA, van der Hoorn A. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high‐grade glioma, a systematic review and meta‐analysis. Eur Radiol. 2017;27:4129‐4144.
    1. Shiroishi MS, Castellazzi G, Boxerman JL, et al. Principles of T2*‐weighted dynamic susceptibility contrast MRI technique in brain tumor imaging. J Magn Reson Imaging. 2014;41:296‐313.
    1. Demeestere J, Wouters A, Christensen S, Lemmens R, Lansberg MG. Review of perfusion imaging in acute ischemic stroke. Stroke. 2020;51:1017‐1024.
    1. Troprès I, Pannetier N, Grand S, et al. Imaging the microvessel caliber and density: principles and applications of microvascular MRI. Magn Reson Med. 2015;73:325‐341.
    1. Jespersen SN, Østergaard L. The roles of cerebral blood flow, capillary transit time heterogeneity and oxygen tension in brain oxygenation and metabolism. J Cereb Blood Flow Metab. 2012;32:264‐277.