Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Jan 6:11:1495543.
doi: 10.3389/fvets.2024.1495543. eCollection 2024.

Use of the oxygen reserve index/FiO2 as a non-invasive index to estimate venous admixture in anesthetized dogs

Affiliations

Use of the oxygen reserve index/FiO2 as a non-invasive index to estimate venous admixture in anesthetized dogs

Luca Bellini et al. Front Vet Sci. .

Abstract

The oxygen reserve index (ORi) is a novel, non-invasive parameter that estimates arterial oxygen partial pressure (PaO2) during hyperoxia when the fraction of inspired oxygen (FiO2) is elevated. This study aimed to assess the utility of the ORi/FiO2 ratio as an index for quantifying F-shunt, serving as an estimate of venous admixture. Anesthetic records were reviewed from 44 dogs undergoing general anesthesia and requiring arterial catheterization. ORi was measured via a CO-oximeter using a probe on the tongue. Paired measurements of PaO2, obtained by blood gas analysis, and ORi were taken at various FiO2 levels to achieve an ORi between 0 and 1. Venous admixture was quantified by F-shunt. Spearman's correlation coefficient assessed the relationship between ORi/FiO2 and F-shunt. Youden's index identified the optimal cut-off point to predict a physiological F-shunt (≤ 10%). A total of 77 paired observations were collected, revealing a moderate negative correlation between F-shunt and ORi/FiO2 (rho = -0.59, p < 0.001). An ORi/FiO2 cut-off of 1.2 demonstrated 80% sensitivity for identifying dogs with an F-shunt ≤10%, with a ROC curve area above 80%. However, the index was less effective at distinguishing dogs with higher shunt fractions. The ORi/FiO2 index identifies dogs with low F-shunt during anesthesia with strong sensitivity and predictive accuracy, potentially ruling out the occurrence of ventilation-perfusion inequality. However, it cannot replace blood gas analysis for quantifying venous admixture.

Keywords: F-shunt; anesthesia; blood gas analysis; dogs; oxygen reserve index.

PubMed Disclaimer

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

Figures

Figure 1
Figure 1
(A) Scatterplot showing the PaO2/FiO2 ratio. (B) Scatterplot showing the ORi/FiO2 ratio. A regression line has been added, with the grey area representing the 95% confidence intervals. ORi, oxygen reserve index; PaO2, partial pressure of oxygen; FiO2, fraction inspired of oxygen; R, Spearman’s correlation coefficient.

References

    1. Teixeira-Neto FJ, Kerr CL. Oxygen therapy, mechanical ventilation, and anesthetic Management of Patients with respiratory disease In: Lamont L, Grimm K, Robertson S, LoveL, Schroeder C, editors. Veterinary anesthesia and analgesia: The sixth edition of Lumb and Jones. Ames, IA: Wiley; (2024). 750–821.
    1. Briganti A, Portela DA, Grasso S, Sgorbini M, Tayari H, Bassini JR, et al. . Accuracy of different oxygenation indices in estimating intrapulmonary shunting at increasing infusion rates of dobutamine in horses under general anaesthesia. Vet J. (2015) 204:351–6. doi: 10.1016/j.tvjl.2015.04.002, PMID: - DOI - PubMed
    1. Araos JD, Larenza MP, Boston RC, De Monte V, De Marzo C, Grasso S, et al. . Use of the oxygen content-based index, Fshunt, as an indicator of pulmonary venous admixture at various inspired oxygen fractions in anesthetized sheep. Am J Vet Res. (2012) 73:2013–20. doi: 10.2460/ajvr.73.12.2013, PMID: - DOI - PubMed
    1. Ceccherini G, Lippi I, Citi S, Perondi F, Pamapanini M, Guidi G, et al. . Continuous positive airway pressure (CPAP) provision with a pediatric helmet for treatment of hypoxemic acute respiratory failure in dogs. J Vet Emerg Crit Care. (2020) 30:41–9. doi: 10.1111/vec.12920, PMID: - DOI - PubMed
    1. Briganti A, Staffieri F, Breghi G, Citi S. Comparison between oxygen indices and computed tomography (CT) for evaluation of atelectasis in dogs. J Vet Emerg Crit Care. (2017) 27:S25. doi: 10.1111/vec.12645, PMID: - DOI - PubMed

LinkOut - more resources