Measurement of intravascular volume status in infants undergoing cranial vault reconstruction for craniosynostosis
- PMID: 39845072
- PMCID: PMC11749892
- DOI: 10.1016/j.sipas.2022.100067
Measurement of intravascular volume status in infants undergoing cranial vault reconstruction for craniosynostosis
Abstract
Introduction: Determining the need, optimal timing, amount, and type of fluid for volume expansion in hypovolemic infants is challenging, due to their small intravascular volumes and robust compensatory reserve. To assess markers of fluid responsiveness in hypovolemic infants, we studied those undergoing cranial vault reconstructive surgery-a procedure associated with significant blood loss. We aimed to determine the ability of the Compensatory Reserve Index (CRI) monitor, which provides a continuous, individual-specific, beat-to-beat estimate of central volume status, to distinguish fluid responders from non-responders.
Methods: A prospective observational pilot study of infants undergoing cranial vault reconstructive surgery for craniosynostosis was performed from May 2019-January 2020. A CardioQ-Esophageal Doppler Monitor, which measures changes in peak aortic velocity, was utilized to distinguish fluid responders- defined as those who demonstrated an increase in peak aortic velocity > 15% following a crystalloid bolus (10 mL/kg). Several static and dynamic variables were analyzed, including the CRI monitor. Each variable's performance was compared using area under the receiver operator curves (AUC), adjusting for age and bolus volume.
Results: Twenty subjects were included and a total of 23 boluses (19 crystalloid and 4 blood) were administered. Of all boluses, 7 (all crystalloid) were provided to fluid responders and 16 to non-responders. There were no statistically significant differences in bolus volumes or bolus durations between responders and non-responders. While adjusting for age and bolus volume, CRI performed similarly to other bedside tools to predict fluid responsiveness with an AUC of 0.7024 (95% CI = 0.459, 0.946).
Conclusion: Distinguishing infants who are fluid responders from those who are not can be challenging. CRI is a continuous, non-invasive measure that was developed using adult waveform data, yet even in very young patients is able to identify those who may benefit from additional volume expansion.
Study type: Therapeutic/Care management.
Level of evidence: Level II.
Keywords: Blood loss; Compensatory reserve index; Fluid resuscitation; Hemodynamic monitoring; Pediatric.
© 2022 The Authors. Published by Elsevier Ltd.
Conflict of interest statement
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Figures
Similar articles
-
Non-invasive assessment of Pulse Wave Transit Time (PWTT) is a poor predictor for intraoperative fluid responsiveness: a prospective observational trial (best-PWTT study).BMC Anesthesiol. 2023 Feb 27;23(1):60. doi: 10.1186/s12871-023-02016-0. BMC Anesthesiol. 2023. PMID: 36849887 Free PMC article.
-
Dynamic behavior of venous collapsibility and central venous pressure during standardized crystalloid bolus: A prospective, observational, pilot study.Int J Crit Illn Inj Sci. 2015 Apr-Jun;5(2):80-4. doi: 10.4103/2229-5151.158392. Int J Crit Illn Inj Sci. 2015. PMID: 26157649 Free PMC article.
-
Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia.J Clin Monit Comput. 2018 Apr;32(2):221-226. doi: 10.1007/s10877-017-0013-3. Epub 2017 Mar 16. J Clin Monit Comput. 2018. PMID: 28299589
-
Respiratory Variation of Internal Carotid Artery Blood Flow Peak Velocity Measured by Transfontanelle Ultrasound to Predict Fluid Responsiveness in Infants: A Prospective Observational Study.Anesthesiology. 2019 May;130(5):719-727. doi: 10.1097/ALN.0000000000002526. Anesthesiology. 2019. PMID: 30907762
-
End-expiratory occlusion maneuver to predict fluid responsiveness in the intensive care unit: an echocardiographic study.Crit Care. 2018 Feb 8;22(1):32. doi: 10.1186/s13054-017-1938-0. Crit Care. 2018. PMID: 29415773 Free PMC article.
References
-
- Swan H.J., Ganz W., Forrester J., Marcus H., Diamond G., Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283(9):447–451. - PubMed
-
- Marik P.E., Cavallazzi R., Vasu T., Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37(9):2642–2647. - PubMed
-
- Marik P.E., Lemson J. Fluid responsiveness: an evolution of our understanding. Br J Anaesth. 2014;112(4):617–620. - PubMed
-
- Broyles M.G., Subramanyam S., Barker A.B., Tolwani A.J. Fluid responsiveness in the critically Ill patient. Adv Chronic Kidney Dis. 2021;28(1):20–28. - PubMed
-
- Shah M.R., Hasselblad V., Stevenson L.W., Binanay C., O'Connor C.M., Sopko G., et al. Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials. JAMA. 2005;294(13):1664–1670. - PubMed