A Technique to Augment Arthroscopic Bankart Repair With or Without a Metal Block: A Comparison
- PMID: 39860621
- PMCID: PMC11766084
- DOI: 10.3390/jcm14020616
A Technique to Augment Arthroscopic Bankart Repair With or Without a Metal Block: A Comparison
Abstract
Introduction: Arthroscopic Bankart repair (ABR) is associated with an increased failure rate over time. The Recenter implant, a metal block, is designed to reinforce capsulolabral repair. The aim of this study was to evaluate whether the addition of the Recenter implant to ABR reduces the rate of recurrence in patients with glenohumeral anterior instability. Materials and Methods: This was a retrospective, multicentric case-control study focusing on patients surgically treated for anterior shoulder instability from February 2012 to November 2019. This study compared patients undergoing ABR augmented with the "Recenter" implant (augmented ABR group) against those receiving traditional ABR. Primary outcomes measured included recurrence rates. Secondary outcome measures included functional scores (Walch-Duplay and the subjective shoulder test [SST], the auto Rowe score, satisfaction, pain, and the presence or absence of subjective subluxation and apprehension), return to sports, the range of motion, as well as other complications. Results: Thirty-two patients with augmented ABR were compared to forty-eight patients in the traditional ABR group, with mean follow-up periods of 5.2 ± 1.3 years and 6.1 ± 1.5 years, respectively. Three patients (9.4%) experienced recurrence in the "Recenter" group, versus eight (16.7%) in the other group (p > 0.05). The Walch-Duplay score was 70.2 ± 8.2 in the "Recenter" group and 64.2 ± 8 in the control group (p > 0.05). The SST score out of 100 was, respectively, 84.6 ± 6 and 81.5 ± 5.5 (p = 0.05). There were no early complications in the implant group. No statistically significant differences were observed between the two groups for the other outcomes. Conclusions: ABR safely restores shoulder stability in selected patients with subcritical glenoid bone deficiency. However, the addition of the Recenter metal implant did not improve outcomes compared to traditional Bankart repair and introduced presumed significant surgical time, technical challenges, and additional costs.
Keywords: Bankart lesions; arthroscopy; experimental; implants; joint instability; shoulder joint.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures







Similar articles
-
Arthroscopic Bristow-Latarjet combined with bankart repair restores shoulder stability in patients with glenoid bone loss.Clin Orthop Relat Res. 2014 Aug;472(8):2413-24. doi: 10.1007/s11999-014-3691-x. Clin Orthop Relat Res. 2014. PMID: 24942959 Free PMC article.
-
[Arthroscopic Bankart Repair with Remplissage for Anterior Instability: Functional Outcomes, Risk of Failure].Acta Chir Orthop Traumatol Cech. 2022;89(6):406-414. Acta Chir Orthop Traumatol Cech. 2022. PMID: 36594687 Czech.
-
Impact of Remplissage on Global Shoulder Outcome: A Long-Term Comparative Study.Arthroscopy. 2019 May;35(5):1362-1367. doi: 10.1016/j.arthro.2019.01.013. Epub 2019 Apr 12. Arthroscopy. 2019. PMID: 30987908
-
Arthroscopic Bankart with remplissage results in lower rates of recurrent instability with similar range of motion compared to isolated arthroscopic Bankart for anterior glenohumeral instability: A systematic review and meta-analysis.Knee Surg Sports Traumatol Arthrosc. 2024 Feb;32(2):243-256. doi: 10.1002/ksa.12054. Epub 2024 Jan 23. Knee Surg Sports Traumatol Arthrosc. 2024. PMID: 38258962
-
Arthroscopic Bankart Repair With Remplissage in Comparison to Bone Block Augmentation for Anterior Shoulder Instability With Bipolar Bone Loss: A Systematic Review.Arthroscopy. 2021 Feb;37(2):706-717. doi: 10.1016/j.arthro.2020.08.033. Epub 2020 Sep 7. Arthroscopy. 2021. PMID: 32911004
References
-
- Thomazeau H., Langlais T., Hardy A., Curado J., Herisson O., Mouton J., Charousset C., Courage O., French Arthroscopy Society. Nourissat G. Long-term, Prospective, Multicenter Study of Isolated Bankart Repair for a Patient Selection Method Based on the Instability Severity Index Score. Am. J. Sports Med. 2019;47:1057–1061. doi: 10.1177/0363546519833920. - DOI - PubMed
LinkOut - more resources
Full Text Sources