. 2025 Mar 5;107(5):476-487.
doi: 10.2106/JBJS.24.00894. Epub 2025 Jan 28.

The Risk of Postoperative Periprosthetic Femoral Fracture After Total Hip Arthroplasty Depends More on Stem Design Than Cement Use: An Analysis of National Health Data from England

Affiliations

The Risk of Postoperative Periprosthetic Femoral Fracture After Total Hip Arthroplasty Depends More on Stem Design Than Cement Use: An Analysis of National Health Data from England

J N Lamb et al. J Bone Joint Surg Am. .

Abstract

Background: In this study, we estimated the risk of surgically treated postoperative periprosthetic femoral fractures (POPFFs) associated with femoral implants frequently used for total hip arthroplasty (THA).

Methods: In this cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020, POPFFs were identified from prospectively collected revision records and national hospital records. POPFF incidence rates, adjusting for potential confounders, were estimated for common stems. Subgroup analyses were performed for patients >70 years of age, with non-osteoarthritic indications, and with femoral neck fracture.

Results: POPFFs occurred in 0.6% (5,100) of 809,832 cases during a median follow-up of 6.5 years (interquartile range [IQR], 3.9 to 9.6 years). After cemented stem implantation, the majority of POPFFs were treated with fixation. Adjusted prosthesis time incidence rates (PTIRs) for POPFFs varied by stem design, regardless of cement fixation. Cemented composite beam (CB) stems demonstrated the lowest risk of POPFF. Collared cementless stems had an equivalent or lower rate of POPFF compared with the current gold standard of a polished taper slip cemented stem.

Conclusions: Cemented CB stems were associated with the lowest POPFF risk, and some cementless stem designs outperformed modern cemented stem designs. Stem design was strongly associated with POPFF risk, regardless of the presence of cement. Surgeons, policymakers, and patients should consider these findings when considering femoral implants in those most at risk for POPFF.

Level of evidence: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.

PubMed Disclaimer

Conflict of interest statement

Disclosure: No external funding was received for this work. The Disclosure of Potential Conflicts of Interest forms are provided with the online version of the article ( http://links.lww.com/JBJS/I387 ).

References

    1. Gitajn IL, Heng M, Weaver MJ, Casemyr N, May C, Vrahas MS, Harris MB. Mortality following surgical management of Vancouver B periprosthetic fractures. J Orthop Trauma. 2017 Jan;31(1):9-14.
    1. Bhattacharyya T, Chang D, Meigs JB, Estok DM 2nd, Malchau H. Mortality after periprosthetic fracture of the femur. J Bone Joint Surg Am. 2007 Dec;89(12):2658-62.
    1. Lamb JN, Nix O, Al-Wizni A, West R, Pandit H. Mortality after postoperative periprosthetic fracture of the femur after hip arthroplasty in the last decade: meta-analysis of 35 cohort studies including 4841 patients. J Arthroplasty. 2022 Feb;37(2):398-405.e1.
    1. Bottle A, Griffiths R, White S, Wynn-Jones H, Aylin P, Moppett I, Chowdhury E, Wilson H, Davies BM. Periprosthetic fractures: the next fragility fracture epidemic? A national observational study. BMJ Open. 2020 Dec 10;10(12):e042371.
    1. Pivec R, Issa K, Kapadia BH, Cherian JJ, Maheshwari AV, Bonutti PM, Mont MA. Incidence and future projections of periprosthetic femoral fracture following primary total hip arthroplasty: an analysis of international registry data. J Long Term Eff Med Implants. 2015;25(4):269-75.

MeSH terms