A straightforward approach for 3D single-shot arterial spin labeling-based brain perfusion imaging: Preventing artifacts due to signal fluctuations
- PMID: 39887515
- PMCID: PMC11972150
- DOI: 10.1002/mrm.30439
A straightforward approach for 3D single-shot arterial spin labeling-based brain perfusion imaging: Preventing artifacts due to signal fluctuations
Abstract
Purpose: The present work aims to evaluate the performance of three-dimensional (3D) single-shot stack-of-spirals turbo FLASH (SOS-TFL) acquisition for pseudo-continuous arterial spin labeling (PCASL) and velocity-selective ASL (VSASL)-based cerebral blood flow (CBF) mapping, as well as VSASL-based cerebral blood volume (CBV) mapping.
Methods: Digital phantom simulations were conducted for both multishot echo planar imaging and spiral trajectories with intershot signal fluctuations. PCASL-derived CBF (PCASL-CBF), VSASL-derived CBF (VSASL-CBF), and CBV (VSASL-CBV) were all acquired using 3D multishot gradient and spin-echo and SOS-TFL acquisitions following background suppression. Both simulation and in vivo images were compared between multishot and single-shot compressed sensing-regularized sensitivity encoding (CS-SENSE) reconstructions.
Results: Artifacts were observed in both simulated multishot echo planar imaging and spiral readouts, as well as in in vivo multishot ASL perfusion images. A high correlation was found between the levels of signal fluctuations among interleaves and the severity of artifacts in both simulated and in vivo data. Image artifacts were more apparent in the inferior region of the brain, especially in CBF scans. These artifacts were effectively eliminated when single-shot CS-SENSE reconstruction was applied to the same data set.
Conclusion: ASL images obtained from 3D segmented gradient and spin-echo or SOS-TFL acquisitions can exhibit artifacts caused by signal fluctuations among different shots, which persist even after the application of background suppression pulses. In contrast, these artifacts were prevented when single-shot CS-SENSE reconstruction was applied to the same SOS-TFL data set.
Keywords: cerebral blood flow; cerebral blood volume; pseudo‐continuous ASL; single‐shot ASL; stack‐of‐spirals turbo FLASH; velocity‐selective arterial spin labeling.
© 2025 International Society for Magnetic Resonance in Medicine.
Similar articles
-
Evaluation of 3D stack-of-spiral turbo FLASH acquisitions for pseudo-continuous and velocity-selective ASL-derived brain perfusion mapping.Magn Reson Med. 2023 Sep;90(3):939-949. doi: 10.1002/mrm.29681. Epub 2023 May 1. Magn Reson Med. 2023. PMID: 37125611 Free PMC article.
-
High-Fidelity MRI Assessment of Cerebral Perfusion in Healthy Neonates Less Than 1 Week of Age.J Magn Reson Imaging. 2025 Sep;62(3):737-748. doi: 10.1002/jmri.29740. Epub 2025 Feb 13. J Magn Reson Imaging. 2025. PMID: 39945520
-
Robust single-shot acquisition of high resolution whole brain ASL images by combining time-dependent 2D CAPIRINHA sampling with spatio-temporal TGV reconstruction.Neuroimage. 2020 Feb 1;206:116337. doi: 10.1016/j.neuroimage.2019.116337. Epub 2019 Nov 9. Neuroimage. 2020. PMID: 31707191 Free PMC article.
-
3D Pseudocontinuous arterial spin labeling in routine clinical practice: A review of clinically significant artifacts.J Magn Reson Imaging. 2016 Jan;43(1):11-27. doi: 10.1002/jmri.24873. Epub 2015 Apr 9. J Magn Reson Imaging. 2016. PMID: 25857715 Review.
-
Velocity-selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation.Magn Reson Med. 2022 Oct;88(4):1528-1547. doi: 10.1002/mrm.29371. Epub 2022 Jul 12. Magn Reson Med. 2022. PMID: 35819184 Free PMC article. Review.
References
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources