Development and Validation of a Gas Chromatography-Mass Spectrometry Method for the Determination of Fentanyl and Butyryl Fentanyl in Oral Fluid
- PMID: 39902462
- PMCID: PMC11789766
- DOI: 10.1002/ansa.202400038
Development and Validation of a Gas Chromatography-Mass Spectrometry Method for the Determination of Fentanyl and Butyryl Fentanyl in Oral Fluid
Abstract
Synthetic opioids are lab-synthesized substances that target the brain's opioid receptors, offering analgesic and sedative effects. Amongst them, fentanyl is one of the most widely used to intervene in chronic pain in moderate to severe cancer situations. Butyryl fentanyl (BF) is a novel synthetic opioid whose use is growing. Its potency is seven times that of morphine and, unlike fentanyl, BF can only be obtained through illegal sources. Fentanyl and its analogues are related to harmful intoxications and an increase in opioid-related mortality in many countries, such as in the United States and Europe in recent years. This work developed and validated an effective and sensitive method based on solid-phase extraction followed by gas chromatography-mass spectrometry (GC-MS) for the determination of fentanyl and BF in oral fluid samples. To the best of our knowledge, it is the first successful attempt to quantify these analytes using GC-MS with a limit of quantification (LOQ) of 1 ng/mL in OF. Intra-day and inter-day percentage coefficient of variation were found within 1%-3% and 1%-14%, respectively, while accuracy ranged from 92% to 102% at four concentration levels (lower LOQ [LLOQ], 3, 20, 40 ng/mL) in accordance with the established criteria. The absolute recovery values were in the range of 80.0%-100.0%. The method was linear for all analytes, with quadratic regression of calibration curves always higher than 0.99. The validated method demonstrated its great potential to detect and quantify fentanyl and its analogue in OF and it can be useful not only in forensic investigations of addiction histories but also in epidemiological studies on the spread of fentanyl and BF among workers and/or drivers.
Keywords: butyryl fentanyl; fentanyl; gas chromatography‐mass spectrometry; oral fluid; synthetic opioids.
© 2024 The Author(s). Analytical Science Advances published by Wiley‐VCH GmbH.
Conflict of interest statement
The authors declare no conflicts of interest.
Figures



Similar articles
-
Determination of synthetic opioids in oral fluid samples using fabric phase sorptive extraction and gas chromatography-mass spectrometry.J Chromatogr A. 2022 Jan 25;1663:462768. doi: 10.1016/j.chroma.2021.462768. Epub 2021 Dec 23. J Chromatogr A. 2022. PMID: 34974368
-
Development of an UPLC-MS/MS method for the analysis of 16 synthetic opioids in segmented hair, and evaluation of the polydrug history in fentanyl analogue users.Forensic Sci Int. 2020 Feb;307:110137. doi: 10.1016/j.forsciint.2019.110137. Epub 2019 Dec 31. Forensic Sci Int. 2020. PMID: 31927248
-
Multiplex detection of 14 fentanyl analogues and U-47700 in biological samples: Application to a panel of French hospitalized patients.Forensic Sci Int. 2020 Dec;317:110437. doi: 10.1016/j.forsciint.2020.110437. Epub 2020 Sep 6. Forensic Sci Int. 2020. PMID: 33007729
-
Fentanyl and its analogues in clinical and forensic toxicology.Przegl Lek. 2005;62(6):581-4. Przegl Lek. 2005. PMID: 16225129 Review.
-
Gas Chromatography-Mass Spectrometry Analysis of Synthetic Opioids Belonging to the Fentanyl Class: A Review.Crit Rev Anal Chem. 2022;52(8):1938-1968. doi: 10.1080/10408347.2021.1927668. Epub 2021 May 30. Crit Rev Anal Chem. 2022. PMID: 34053394 Review.
References
-
- Davis M. P., “Fentanyl for Breakthrough Pain: A Systematic Review,” Expert Review of Neurotherapeutics 11 (2011): 1197–1216. - PubMed
-
- Bista S. R., Haywood A., Norris R., et al., “Saliva versus Plasma for Pharmacokinetic and Pharmacodynamic Studies of Fentanyl in Patients With Cancer,” Clinical Therapeutics 37 (2015): 2468–2475. - PubMed
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous