Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1985 May;26(5):698-710.

Quantitative vitreous fluorophotometry applying a mathematical model of the eye

  • PMID: 3997419

Quantitative vitreous fluorophotometry applying a mathematical model of the eye

H Lund-Andersen et al. Invest Ophthalmol Vis Sci. 1985 May.

Abstract

A slit-lamp fluorophotometric method is presented that permits calculation of a blood-retinal barrier permeability to fluorescein (P) and a diffusion coefficient for fluorescein in the vitreous body (D). The calculations are performed by relating the time course of the free--not protein bound--fluorescein concentration in the bloodstream with the fluorescein concentration profile in the vitreous body. The combination is performed automatically on a computer by applying a simplified mathematical model of the eye. P refers to the area of the barrier of the model eye. In a group of six normal persons, the mean P was (1.1 +/- 0.4) X 10(-7) cm/sec (mean +/- SD), while in six diabetic patients with background retinopathy and macular edema the mean P was (7.1 +/- 3.8 ) X 10(-7) cm/sec. The mean D was (7.4 +/- 3.4) X 10(-6) cm2/sec in the normal group and (9.6 +/- 2.0) X 10(-6) cm2/sec in diabetic patients, corresponding as a first approximation to free diffusion in water. Model calculations show that knowing the fluorescein concentration in the bloodstream is considerably significant for the calculation of the permeability, contributing factors up to 50%. For the low-permeation situation, subtraction of the preinjection scan contributes a factor of 50% for both permeability and diffusion coefficient. The exact placement in the vitreous body of the concentration profile, by applying a formalism that transforms slit-lamp movement to intraocular distance, contributes a factor of 20% on the diffusion coefficient. The permeability obtained with the model can be calculated as the ratio between area of vitreous and plasma fluorescein concentration curves within 20%. Active transport of fluorescein across the blood-retinal barrier in the direction of vitreous to blood does not seem to be significant within the first 2 hr after fluorescein injection.

PubMed Disclaimer

Publication types

LinkOut - more resources