Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2025 Jun;69(6):837-845.
doi: 10.1016/j.ejvs.2025.02.030. Epub 2025 Feb 21.

Use of an Off the Shelf Inner Branch Thoraco-abdominal Endograft for the Treatment of Juxtarenal and Pararenal Aortic Aneurysms

Collaborators, Affiliations
Free article
Observational Study

Use of an Off the Shelf Inner Branch Thoraco-abdominal Endograft for the Treatment of Juxtarenal and Pararenal Aortic Aneurysms

Francesco Squizzato et al. Eur J Vasc Endovasc Surg. 2025 Jun.
Free article

Abstract

Objective: To investigate outcomes of an off the shelf pre-loaded inner branched endograft (E-nside) for the treatment of juxtarenal and pararenal abdominal aortic aneurysms (JP-AAAs).

Methods: Data from a multicentre registry (INBREED), including patients treated with the E-nside endograft, were collected and analysed prospectively. Patients treated for JP-AAA were included. Pre-operative clinical and anatomical characteristics, procedural data, and 30 day and one year outcomes were recorded. Endpoints were technical success, 30 day death, major adverse events (MAEs), and one year freedom from target vessel instability.

Results: Of 185 consecutively treated patients, 47 (25.4%) had a JP-AAA (juxtarenal n = 10, 21%; pararenal n = 37, 79%) and were included in the study; 183 target vessels were incorporated through an inner branch. Procedural setting was emergency or urgent in 18 patients (38%) owing to a contained aortic rupture (n = 2, 4%), symptomatic aneurysm (n = 4, 9%), or aneurysm > 70 mm (n = 12, 26%). The mean length of aortic coverage above the coeliac trunk was 116 ± 7 mm. Technical success was 100% and 30 day mortality rate 4% (n = 2 urgent cases). The 30 day cumulative MAE rate was 26% (n = 12): two stroke (4%); and seven spinal cord ischaemia (15%), with six in an elective setting (21%) and one in an urgent setting (6%), and five leading to permanent paraplegia or paraparesis (10%). Freedom from target vessel instability was 99% after 30 days and 97 ± 3% after one year.

Conclusion: Use of an off the shelf inner branched device for treating JP-AAA was feasible in urgent and elective settings, with high technical success and satisfactory target vessel stability at one year. In the treatment of JP-AAA, stroke and spinal cord ischaemia may be associated with arm access and the increased aortic coverage that the design brings.

Keywords: Abdominal aortic aneurysm; B-EVAR; Inner branch; Juxtarenal aneurysm; Off the shelf; Pararenal aneurysm.