A convolution method of calculating dose for 15-MV x rays
- PMID: 4000075
- DOI: 10.1118/1.595774
A convolution method of calculating dose for 15-MV x rays
Abstract
Arrays were generated using the Monte Carlo method representing the energy absorbed throughout waterlike phantoms from charged particles and scatter radiation set in motion by primary interactions at one location. The resulting "dose spread arrays" were normalized to the collision fraction of the kinetic energy released by the primary photons. These arrays are convolved with the relative primary fluence interacting in a phantom to obtain three-dimensional dose distributions. The method gives good agreement for the 15-MV x-ray dose in electronic disequilibrium situations, such as the buildup region, near beam boundaries, and near low-density heterogeneities.
Similar articles
-
Accounting for primary electron scatter in x-ray beam convolution calculations.Med Phys. 1995 Sep;22(9):1413-8. doi: 10.1118/1.597623. Med Phys. 1995. PMID: 8531866
-
10-MV x-ray primary and scatter dose calculation using convolutions.Med Phys. 1990 Mar-Apr;17(2):203-11. doi: 10.1118/1.596499. Med Phys. 1990. PMID: 2333047
-
A two-step algorithm for predicting portal dose images in arbitrary detectors.Med Phys. 2000 Sep;27(9):2109-16. doi: 10.1118/1.1289375. Med Phys. 2000. PMID: 11011740
-
Radiation dose in diagnostic radiology: Monte Carlo simulation studies.Med Phys. 1984 Jul-Aug;11(4):480-90. doi: 10.1118/1.595541. Med Phys. 1984. PMID: 6482844
-
Electron disequilibrium in high-energy x-ray beams.Med Phys. 1996 Nov;23(11):1867-71. doi: 10.1118/1.597749. Med Phys. 1996. PMID: 8947900
Cited by
-
A longitudinal evaluation of improvements in treatment plan quality for lung cancer with volumetric modulated arc therapy.J Appl Clin Med Phys. 2020 Jun;21(6):33-43. doi: 10.1002/acm2.12863. Epub 2020 Apr 1. J Appl Clin Med Phys. 2020. PMID: 32237271 Free PMC article.
-
Analytical model for out-of-field dose in photon craniospinal irradiation.Phys Med Biol. 2013 Nov 7;58(21):7463-79. doi: 10.1088/0031-9155/58/21/7463. Epub 2013 Oct 8. Phys Med Biol. 2013. PMID: 24099782 Free PMC article.
-
Dosimetric accuracy of tomotherapy dose calculation in thorax lesions.Radiat Oncol. 2011 Feb 9;6:14. doi: 10.1186/1748-717X-6-14. Radiat Oncol. 2011. PMID: 21306629 Free PMC article.
-
The effect of gantry spacing resolution on plan quality in a single modulated arc optimization.J Appl Clin Med Phys. 2011 Nov 15;12(4):3603. doi: 10.1120/jacmp.v12i4.3603. J Appl Clin Med Phys. 2011. PMID: 22089019 Free PMC article.
-
Out-of-field doses from radiotherapy using photon beams: A comparative study for a pediatric renal treatment.J Appl Clin Med Phys. 2021 Mar;22(3):94-106. doi: 10.1002/acm2.13182. Epub 2021 Feb 5. J Appl Clin Med Phys. 2021. PMID: 33547766 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources