Physiological limits in lifting
- PMID: 4003273
- DOI: 10.1080/15298668591394699
Physiological limits in lifting
Abstract
Two different experiments were conducted to study the effects of frequency, height and load of lift on computed maximal oxygen uptake and to compare the data obtained to a standard bicycle ergometer. A progressive submaximal technique was used to predict maximal oxygen uptake. The results of the present study revealed that across all heights, an increase in either the frequency of lift or load of lift was accompanied by an increase in computed maximal oxygen uptake; however, all maximal oxygen uptake values reported showed a tendency to level off beyond the frequency of five lifts/min. The results also showed that combined arm and leg lifting recorded the highest maximal oxygen uptake followed by leg lifting then arm lifting, respectively. Maximal oxygen uptake values obtained for lifting tasks were much lower than those obtained for a bicycle ergometer. It is therefore recommended that limits for continuous work for a lifting task be based on the attainable maximal oxygen uptake for that particular task and not on a maximal oxygen uptake obtained from another task such as a bicycle ergometer test.
Similar articles
-
Endurance time and physiological responses to prolonged arm lifting.Ergonomics. 1991 Mar;34(3):335-42. doi: 10.1080/00140139108967317. Ergonomics. 1991. PMID: 2055219
-
Maximum acceptable weights for asymmetric lifting of Chinese females.Appl Ergon. 2003 May;34(3):215-24. doi: 10.1016/S0003-6870(03)00010-3. Appl Ergon. 2003. PMID: 12737921
-
Effect of semi-rigid lumbosacral orthosis use on oxygen consumption during repetitive stoop and squat lifting.Ergonomics. 1998 Jun;41(6):790-7. doi: 10.1080/001401398186649. Ergonomics. 1998. PMID: 9629064 Clinical Trial.
-
Metabolic and cardiorespiratory responses to continuous box lifting and lowering in nonimpaired subjects.J Orthop Sports Phys Ther. 2000 May;30(5):249-57; discussion 258-62. doi: 10.2519/jospt.2000.30.5.249. J Orthop Sports Phys Ther. 2000. PMID: 10817412
-
Physiological guidelines for the design of manual lifting and lowering tasks: the state of the art.Am Ind Hyg Assoc J. 1988 Apr;49(4):150-60. doi: 10.1080/15298668891379549. Am Ind Hyg Assoc J. 1988. PMID: 3287879 Review.
Cited by
-
Comparisons of physiological and perceptual responses in healthy men and women during standardized arm cranking and task-specific pushing-pulling.Int Arch Occup Environ Health. 2006 Jun;79(6):509-20. doi: 10.1007/s00420-005-0076-1. Epub 2005 Dec 31. Int Arch Occup Environ Health. 2006. PMID: 16437220
-
Maximal aerobic capacity for repetitive lifting: comparison with three standard exercise testing modes.Eur J Appl Physiol Occup Physiol. 1988;57(6):753-60. doi: 10.1007/BF01075999. Eur J Appl Physiol Occup Physiol. 1988. PMID: 3416862
-
Physiological and subjective responses to maximal repetitive lifting employing stoop and squat technique.Eur J Appl Physiol Occup Physiol. 1993;67(4):291-7. doi: 10.1007/BF00357625. Eur J Appl Physiol Occup Physiol. 1993. PMID: 8299594
-
Role of obesity on cerebral hemodynamics and cardiorespiratory responses in healthy men during repetitive incremental lifting.Eur J Appl Physiol. 2015 Sep;115(9):1905-17. doi: 10.1007/s00421-015-3171-3. Epub 2015 Apr 21. Eur J Appl Physiol. 2015. PMID: 25896283 Clinical Trial.