Reliability of Dynamic Balance Test with A Mobile Application of Physics Toolbox Suite
- PMID: 40046217
- PMCID: PMC11877298
- DOI: 10.52082/jssm.2025.154
Reliability of Dynamic Balance Test with A Mobile Application of Physics Toolbox Suite
Abstract
Although mobile applications are used as an alternative to expensive and difficult to access systems used to evaluate dynamic balance, existing applications have some shortcomings. This study aimed to evaluate the reliability of the Physics Toolbox Suite mobile application, which can obtain objective data for dynamic balance measurements in healthy adults, shorten the duration of measurements, and minimize the number of measurement equipment. The dynamic balance of 22 university students (9 male, 13 female, aged 20.3 (± 1.13 years)) was evaluated using the Physics Toolbox Suite mobile application in three test sessions with a 1-week interval. Anterior-posterior stability index (APSI), medial-lateral stability index (MLS), and overall stability index (OSI) of dynamic balance were calculated. Interclass Correlation Coefficients (ICC), Minimal Detectable Change (MDC), Standard Error of Measurement (SEM), and Coefficient of Variation for SEM (CVSEM) were evaluated as indicators of intra- and inter-rater reliability. The mean APSI, MLSI, and OSI scores (Standard deviation) were 2.59 (0.69), 2.21 (0.68), and 3.58 (0.94), respectively. In the evaluation made with the Physics Toolbox Suite mobile application, APSI scores had good intra-rater (ICC(3,1) = 0.67) and inter-rater reliability (ICC(3,1) = 0.73), MLSI scores had high intra-rater (ICC(3,1) = 0.90) with good inter-rater reliability (ICC(3,1) = 0.71), and OSI scores had high intra- rater (ICC(3,1) = 0.87) with good inter-rater reliability (ICC(3,1) = 0.73). The Physics Toolbox Suite Mobile Application can be used as a reliable objective tool to assess dynamic balance among healthcare professionals and athletes.
Keywords: Balance test; dynamic balance; reliability; smartphone application.
© Journal of Sports Science and Medicine.
Figures



References
-
- Akhbari B., Salavati M., Mohammadi F., Safavi-farokhi Z. (2015) Intra- and inter-session reliability of static and dynamic postural control in participants with and without patellofemoral pain syndrome. Physiotherapy Canada 67, 248-253.https://doi.org/10.3138/ptc.2014-51 10.3138/ptc.2014-51 - DOI - PMC - PubMed
-
- Alexander K. (2015) Instruments in your pocket. Mechanical Engineering 137, 42-45.https://doi.org/10.1115/1.2015-Sep-3 10.1115/1.2015-Sep-3 - DOI
-
- Amick R.Z., Chaparro A., Patterson J.A., Jorgensen M.J. (2015) Test-retest reliability of the sway balance mobile application. Journal of Mobile Technology in Medicine 4, 40.https://doi.org/10.7309/jmtm.4.2.6 10.7309/jmtm.4.2.6 - DOI
-
- Beckerman H., Roebroeck M.E., Lankhorst G.J., Becher J.G., Bezemer P.D., Verbeek A.L.M. (2001) Smallest real difference, a link between reproducibility and responsiveness. Quality of Life Research 10, 571-578.https://doi.org/10.1023/a:1013138911638 10.1023/a:1013138911638 - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources