Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1985 May 1;227(3):957-63.
doi: 10.1042/bj2270957.

Affinity-purified antibodies of defined specificity for use in a solid-phase microplate radioimmunoassay of human Tamm-Horsfall glycoprotein in urine

Affinity-purified antibodies of defined specificity for use in a solid-phase microplate radioimmunoassay of human Tamm-Horsfall glycoprotein in urine

J S Hunt et al. Biochem J. .

Abstract

Rabbit antibodies to human Tamm-Horsfall glycoprotein (prepared by salt precipitation from normal urine) were purified by affinity chromatography using columns containing Tamm-Horsfall glycoprotein linked to CNBr-activated Sepharose 4B. The specificity of these antibodies was determined by analysis of their binding characteristics on Western blots of Tamm-Horsfall protein from sodium dodecyl sulphate/polyacrylamide gradient gels and comparison with the reactivity of monoclonal antibodies to this glycoprotein. Optimal conditions of adsorption to poly(vinyl chloride) microtitre plates were established such that these purified antibodies could be used in a solid-phase radioimmunoassay for the determination of urinary Tamm-Horsfall-glycoprotein concentration. The specificity of the immunoassay was confirmed by competitive inhibition of the urinary Tamm-Horsfall glycoprotein by purified freeze-dried material in solution. A standard curve obtained with this material showed the radioimmunoassay to have a sensitivity of at least 5 ng/ml, with linearity between 30 and 600 ng/ml. The mean coefficient of variation over the linear section of the curve was 11.3 +/- 2.2% (n = 13). The effects of dialysis and freezing of urine samples before determination of Tamm-Horsfall-glycoprotein concentrations were investigated and the mean 24 h urinary excretion rate in 60 normal donors was shown to be 84.9 +/- 44.1 mg.

PubMed Disclaimer

References

    1. J Lab Clin Med. 1974 Nov;84(5):771-6 - PubMed
    1. Biochem J. 1981 Feb 15;194(2):561-8 - PubMed
    1. Clin Chim Acta. 1977 Aug 1;78(3):391-400 - PubMed
    1. J Clin Pathol. 1962 Jul;15(4):367-73 - PubMed
    1. Nature. 1970 Aug 15;227(5259):680-5 - PubMed

Publication types