Abstract
The use of the Wiener filter is proposed for temporal filtering of nuclear medicine dynamic studies. This filter adapts to the signal and noise levels of each pixel activity curve in a dynamic study to produce an "optimal" suppression of noise, while maintaining the signal content of the curve. The filter is derived to be a simple function of the power spectrum of the time-activity curve. Examples of its use for temporally filtering gated blood-pool studies for cine viewing and functional image formation are shown.
Similar articles
-
A Wiener filter for nuclear medicine images.Med Phys. 1983 Nov-Dec;10(6):876-80. doi: 10.1118/1.595352. Med Phys. 1983. PMID: 6656698
-
The derivation and verification of a non-stationary, optimal smoothing filter for nuclear medicine image data.Phys Med Biol. 1990 Dec;35(12):1641-62. doi: 10.1088/0031-9155/35/12/005. Phys Med Biol. 1990. PMID: 2284335
-
Use of finite-memory Wiener filters in scintigram processing.Eur J Nucl Med. 1980 Oct;5(5):447-52. doi: 10.1007/BF00261790. Eur J Nucl Med. 1980. PMID: 7215367
-
Array processors: an introduction to their architecture, software, and applications in nuclear medicine.J Nucl Med. 1983 Nov;24(11):1072-9. J Nucl Med. 1983. PMID: 6355407 Review.
-
Model identification and estimation of organ-function parameters using radioactive tracers and the impulse-response function.Eur J Nucl Med. 1985;11(6-7):265-74. doi: 10.1007/BF00279082. Eur J Nucl Med. 1985. PMID: 3908109 Review.
Cited by
-
4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.IEEE Trans Med Imaging. 2017 Aug;36(8):1626-1635. doi: 10.1109/TMI.2017.2690819. Epub 2017 Apr 4. IEEE Trans Med Imaging. 2017. PMID: 28391190 Free PMC article.
-
Deformable left-ventricle mesh model for motion-compensated filtering in cardiac gated SPECT.Med Phys. 2010 Oct;37(10):5471-81. doi: 10.1118/1.3483098. Med Phys. 2010. PMID: 21089783 Free PMC article.
-
PET image reconstruction using kernel method.IEEE Trans Med Imaging. 2015 Jan;34(1):61-71. doi: 10.1109/TMI.2014.2343916. Epub 2014 Jul 30. IEEE Trans Med Imaging. 2015. PMID: 25095249 Free PMC article.
-
Motion-compensated temporal summation of cardiac gated SPECT images using a deformable mesh model.Annu Int Conf IEEE Eng Med Biol Soc. 2009;2009:3657-60. doi: 10.1109/IEMBS.2009.5333693. Annu Int Conf IEEE Eng Med Biol Soc. 2009. PMID: 19964313 Free PMC article.
-
Gating, enhanced gating, and beyond: information utilization strategies for motion management, applied to preclinical PET.EJNMMI Res. 2013 Apr 24;3(1):29. doi: 10.1186/2191-219X-3-29. EJNMMI Res. 2013. PMID: 23618039 Free PMC article.
References
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical