. 2025 May;72(5):636-645.
doi: 10.1109/TUFFC.2025.3553735. Epub 2025 May 7.

Computational Super-Resolution for Ultrasound Localization Microscopy Through Solving an Inverse Problem

Computational Super-Resolution for Ultrasound Localization Microscopy Through Solving an Inverse Problem

Vassili Pustovalov et al. IEEE Trans Ultrason Ferroelectr Freq Control. 2025 May.

Abstract

Ultrasound localization microscopy (ULM) represents a significant advancement over traditional ultrasound (US) imaging, enabling super-resolution (SR) imaging of microvascular structures with unprecedented detail, by using microbubbles (MBs) as highly reflective contrast agents. After injection into the bloodstream, MBs are localized in US images to reconstruct the microvasculature. However, this technique faces a tradeoff between MB localization accuracy and acquisition time. Perfusion with low MB concentrations reduces signal overlap and achieves high localization accuracy but requires extended acquisition times. Conversely, higher MB concentrations shorten acquisition times but increase signal overlap, limiting localization precision. Traditionally, ULM consists of five main steps: tissue filtering, MB detection, MB super-localization, tracking, and rendering. In this study, we present a novel approach that combines a robust principal component analysis (RPCA) with a computational SR technique, replacing the first three steps of ULM with a single process based on solving an SR inverse problem. This method isolates MB signals from background noise and enhances the localization of overlapping MBs, thereby improving overall ULM performance. The experimental results from simulated and in vivo data demonstrate that our proposed approach increases the SR factor by up to 30% and enhances the contrast ratio (CR) by 3.5 dB. It also produces comparable results across other image quality metrics. These improvements enable denser, higher contrast vascular images.

PubMed Disclaimer