Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Aug;33(8):2917-2927.
doi: 10.1002/ksa.12659. Epub 2025 Mar 25.

Tibial implant varus >3° does not adversely affect outcomes or revision rates in functionally aligned image-based robotic total knee arthroplasty in a minimum of 2-year follow-up

Affiliations

Tibial implant varus >3° does not adversely affect outcomes or revision rates in functionally aligned image-based robotic total knee arthroplasty in a minimum of 2-year follow-up

Christos Koutserimpas et al. Knee Surg Sports Traumatol Arthrosc. 2025 Aug.

Abstract

Purpose: Functional alignment (FA) aims to restore knee kinematics by balancing laxities and adapting implant positioning. This study evaluates safety and outcomes of >3° varus tibial positioning in patients with varus deformity undergoing robotic-assisted total knee arthroplasty (TKA).

Methods: This retrospective study included 337 patients with varus deformity undergoing robotic-assisted TKA with FA principles with a minimum of 2-year follow-up. Patients were divided into two groups based on tibial varus positioning: ≤3° varus: Group A and >3° varus: Group B. Preoperative and postoperative coronal alignment, implant positioning, and outcomes were assessed using the Knee Society Score (KSS) and the Forgotten Joint Score (FJS) at final follow-up. The primary outcome was implants' survivorship, and secondary outcomes included complication rates and functional scores. Statistical analyses included Mann-Whitney and Chi-square tests for group comparisons, Kaplan-Meier survival analysis for implant survivorship, and multivariate regression for key covariates.

Results: Implant survivorship was 99.4% in Group B over a median follow-up of 30 months, with one revision due to aseptic loosening and 100% in Group A (p = 0.36). The overall complication rates were 12.7% in Group A and 10.2% in B (p = 0.48). The median KSS-knee and function scores were 94.5 and 90 in Group A and 94 and 90 in B (p = 0.88 and 0.8, respectively). The final FJS was 82 in Group A and 84 in B (p = 0.8). No significant differences were observed in postoperative knee range of motion between the two groups. Multivariate regression analysis showed that none of the included covariates were statistically significant predictors of implant failure.

Conclusion: FA in robotic-assisted TKA with tibial positioning >3° varus seems to be safe and reliable in patients with varus deformity, demonstrating similar revision rates, implant survivorship, and outcomes compared to the ≤3° tibial varus group.

Level of evidence: Level III.

Keywords: functional alignment; personalised alignment; robotic knee; total knee; total knee replacement.

PubMed Disclaimer

Similar articles

Cited by

References

REFERENCES

    1. Abdel MP, Ollivier M, Parratte S, Trousdale RT, Berry DJ, Pagnano MW. Effect of postoperative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement: a concise follow‐up at 20 years. J Bone Jt Surg. 2018;100(6):472–478.
    1. Beckers G, Meneghini RM, Hirschmann MT, Kostretzis L, Kiss M‐O, Vendittoli P‐A. Ten flaws of systematic mechanical alignment total knee arthroplasty. J Arthroplasty. 2024;39(3):591–599.
    1. Begum FA, Kayani B, Magan AA, Chang JS, Haddad FS. Current concepts in total knee arthroplasty: mechanical, kinematic, anatomical, and functional alignment. Bone Jt Open. 2021;2(6):397–404.
    1. Brown ML, Javidan P, Early S, Bugbee W. Evolving etiologies and rates of revision total knee arthroplasty: a 10‐year institutional report. Arthroplasty. 2022;4(1):39.
    1. Chang JS, Kayani B, Wallace C, Haddad FS. Functional alignment achieves soft‐tissue balance in total knee arthroplasty as measured with quantitative sensor‐guided technology. Bone Jt J. 2021;103–B(3):507–514.