Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2025 Mar 28;67(4):ezaf103.
doi: 10.1093/ejcts/ezaf103.

Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement†

Affiliations
Multicenter Study

Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement†

Lawrence M Wei et al. Eur J Cardiothorac Surg. .

Abstract

Objectives: In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience.

Methods: All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020-7/2024) were evaluated using a central database with 1 year follow-up.

Results: A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency.

Conclusions: RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.

Keywords: Robotic valve surgery; Robotic-assisted aortic valve replacement.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources