Reply to comments on "Comparative analysis of LMA Blockbuster® clinical performance: Blind versus Miller laryngoscope-guided insertion in paediatric general anaesthesia - A double-blinded, randomised controlled trial"
- PMID: 40160908
- PMCID: PMC11949404
- DOI: 10.4103/ija.ija_1159_24
Reply to comments on "Comparative analysis of LMA Blockbuster® clinical performance: Blind versus Miller laryngoscope-guided insertion in paediatric general anaesthesia - A double-blinded, randomised controlled trial"
Conflict of interest statement
There are no conflicts of interest.
Similar articles
-
Comparative analysis of LMA Blockbuster® clinical performance: Blind versus Miller laryngoscope-guided insertion in paediatric general anaesthesia - A double-blinded, randomised controlled trial.Indian J Anaesth. 2024 Oct;68(10):875-881. doi: 10.4103/ija.ija_186_24. Epub 2024 Sep 14. Indian J Anaesth. 2024. PMID: 39449841 Free PMC article.
-
Comment On 'Comparative analysis of LMA Blockbuster® clinical performance: Blind versus Miller laryngoscope-guided insertion in paediatric general anaesthesia - A double-blinded, randomised controlled trial'.Indian J Anaesth. 2025 Feb;69(2):253-254. doi: 10.4103/ija.ija_986_24. Epub 2025 Jan 29. Indian J Anaesth. 2025. PMID: 40160917 Free PMC article. No abstract available.
-
Comparison of success rate of BlockBuster® versus Fastrach® LMA as conduit for blind endotracheal intubation: A prospective randomised trial.Indian J Anaesth. 2019 Dec;63(12):988-994. doi: 10.4103/ija.IJA_396_19. Epub 2019 Dec 11. Indian J Anaesth. 2019. PMID: 31879422 Free PMC article.
-
Comparison of clinical performance of Ambu® AuraGain™ and BlockBuster® in anaesthetised preschool children-A randomised controlled trial.Indian J Anaesth. 2023 May;67(5):420-425. doi: 10.4103/ija.ija_286_22. Epub 2023 May 11. Indian J Anaesth. 2023. PMID: 37333705 Free PMC article.
-
Comparison of Laryngoscope-Guided Insertion and Standard Blind Insertion of the Laryngeal Mask Airway: A Systematic Review and Meta-Analysis.Anesthesiol Res Pract. 2025 Mar 18;2025:1224567. doi: 10.1155/anrp/1224567. eCollection 2025. Anesthesiol Res Pract. 2025. PMID: 40134853 Free PMC article. Review.
References
-
- Bihani P, Shivanand, Jaju R, Paliwal N, Janweja S, Vyas A. Comparative analysis of LMA Blockbuster® clinical performance: Blind versus Miller laryngoscope-guided insertion in paediatric general anaesthesia – A double-blinded, randomised controlled trial. Indian J Anaesth. 2024;68:875–81. - PMC - PubMed
-
- Van Zundert AA, Kumar CM, Van Zundert TC. Malpositioning of supraglottic airway devices: Preventive and corrective strategies. Br J Anaesth. 2016;116:579–82. - PubMed
-
- Kumar KR, Soni L, Sinha R, Muthiah T, Patel N, Shende DK, et al. Comparison of Ambu AuraGain and BlockBuster laryngeal mask for controlled ventilation in children undergoing minor surgical procedures under general anesthesia: A prospective randomised controlled study. Paediatr Anaesth. 2023;33:474–80. - PubMed