Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 Oct 1;60(10):669-678.
doi: 10.1097/RLI.0000000000001186.

Fast and Robust Single-Shot Cine Cardiac MRI Using Deep Learning Super-Resolution Reconstruction

Affiliations

Fast and Robust Single-Shot Cine Cardiac MRI Using Deep Learning Super-Resolution Reconstruction

Taraneh Aziz-Safaie et al. Invest Radiol. .

Abstract

Objective: The aim of the study was to compare the diagnostic quality of deep learning (DL) reconstructed balanced steady-state free precession (bSSFP) single-shot (SSH) cine images with standard, multishot (also: segmented) bSSFP cine (standard cine) in cardiac MRI.

Methods and materials: This prospective study was performed in a cohort of participants with clinical indication for cardiac MRI. SSH compressed-sensing bSSFP cine and standard multishot cine were acquired with breath-holding and electrocardiogram-gating in short-axis view at 1.5 Tesla. SSH cine images were reconstructed using an industry-developed DL super-resolution algorithm (DL-SSH cine). Two readers evaluated diagnostic quality (endocardial edge definition, blood pool to myocardium contrast and artifact burden) from 1 (nondiagnostic) to 5 (excellent). Functional left ventricular (LV) parameters were assessed in both sequences. Edge rise distance, apparent signal-to-noise ratio (aSNR) and contrast-to-noise ratio were calculated. Statistical analysis for the comparison of DL-SSH cine and standard cine included the Student's t-test, Wilcoxon signed-rank test, Bland-Altman analysis, and Pearson correlation.

Results: Forty-five participants (mean age: 50 years ±18; 30 men) were included. Mean total scan time was 65% lower for DL-SSH cine compared to standard cine (92 ± 8 s vs 265 ± 33 s; P < 0.0001). DL-SSH cine showed high ratings for subjective image quality (eg, contrast: 5 [interquartile range {IQR}, 5-5] vs 5 [IQR, 5-5], P = 0.01; artifacts: 4.5 [IQR, 4-5] vs 5 [IQR, 4-5], P = 0.26), with superior values for sharpness parameters (endocardial edge definition: 5 [IQR, 5-5] vs 5 [IQR, 4-5], P < 0.0001; edge rise distance: 1.9 [IQR, 1.8-2.3] vs 2.5 [IQR, 2.3-2.6], P < 0.0001) compared to standard cine. No significant differences were found in the comparison of objective metrics between DL-SSH and standard cine (eg, aSNR: 49 [IQR, 38.5-70] vs 52 [IQR, 38-66.5], P = 0.74). Strong correlation was found between DL-SSH cine and standard cine for the assessment of functional LV parameters (eg, ejection fraction: r = 0.95). Subgroup analysis of participants with arrhythmia or unreliable breath-holding (n = 14/45, 31%) showed better image quality ratings for DL-SSH cine compared to standard cine (eg, artifacts: 4 [IQR, 4-5] vs 4 [IQR, 3-5], P = 0.04).

Conclusions: DL reconstruction of SSH cine sequence in cardiac MRI enabled accelerated acquisition times and noninferior diagnostic quality compared to standard cine imaging, with even superior diagnostic quality in participants with arrhythmia or unreliable breath-holding.

Keywords: cardiac imaging techniques; cine magnetic resonance imaging; deep learning; image reconstruction; steady-state free precession MRI.

PubMed Disclaimer

Conflict of interest statement

Conflicts of interest and sources of funding: none declared.

References

    1. Kramer CM, Barkhausen J, Bucciarelli-Ducci C, et al. Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update. J Cardiovasc Magn Reson. 2020;22:17.
    1. Pednekar A, Kocaoglu M, Wang H, et al. Accelerated cine cardiac MRI using deep learning-based reconstruction: a systematic evaluation. J Magn Reson Imaging. 2024;60:640–650.
    1. Zou Q, Xu H, Fu C, et al. Utility of single-shot compressed sensing cardiac magnetic resonance cine imaging for assessment of biventricular function in free-breathing and arrhythmic pediatric patients. Int J Cardiol. 2021;338:258–264.
    1. Schwab F, Schwarz F, Dietrich O, et al. Free breathing real-time cardiac cine imaging with improved spatial resolution at 3 T. Invest Radiol. 2013;48 https://journals.lww.com/investigativeradiology/fulltext/2013/03000/free... :158–166.
    1. Krishnamurthy R, Pednekar A, Cheong B, et al. High temporal resolution SSFP cine MRI for estimation of left ventricular diastolic parameters. J Magn Reson Imaging. 2010;31:872–880.

LinkOut - more resources