Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1985 Jul;22(1):62-7.
doi: 10.1128/jcm.22.1.62-67.1985.

Clinical evaluation of three rapid methods for the detection of significant bacteriuria

Comparative Study

Clinical evaluation of three rapid methods for the detection of significant bacteriuria

E Bixler-Forell et al. J Clin Microbiol. 1985 Jul.

Abstract

Random urine specimens (848) were screened for significant bacteriuria by using the 30-min Lumac (3M, St. Paul, Minn.), the 2-min Bac-T-Screen (Marion Laboratories, Inc., Kansas City, Mo.), and the 13-h AutoMicrobic system (AMS) urine identification card (Vitek Systems, Inc., Hazelwood, Mo.). MacConkey and 5% sheep blood agar plates were inoculated with a 10(-4) dilution of urine and used for the reference method. Bac-T-Screen results were uninterpretable for 9.1% of the specimens owing to either urine sample pigmentation (5.3%) or clogging of the filter (3.8%). Screen-negative urine specimens made up 49.6, 57.2, and 48.5% of the total number of specimens evaluated with AMS, Lumac, and Bac-T-Screen, respectively. False-positive results with Lumac and Bac-T-Screen were 20.6 and 22.3%, respectively. False-negative results for cultures with greater than or equal to 10(4) CFU/ml were 22.0% with AMS, 29.4% with Lumac, and 25.5% with Bac-T-Screen, and false-negative results for cultures with greater than or equal to 10(5) CFU/ml were 29.6% with AMS, 9.9% with Lumac, and 7.0% with Bac-T-Screen. For each system, greater than 70% of false-negatives at greater than or equal to 10(5) CFU/ml consisted of mixed or pure cultures of common contaminants. With any of these screening methods, a clinically significant isolate at greater than or equal to 10(5) CFU/ml would rarely be missed (less than or equal to 1.7% for all systems). A cost-effective and rapid approach to urine microbiology could consist of screening out negative specimens by either Lumac or Bac-T-Screen and processing only screen-positive specimens by the AMS.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Clin Pathol. 1979 Feb;71(2):177-83 - PubMed
    1. J Clin Pathol. 1981 Feb;34(2):194-8 - PubMed
    1. Trans Assoc Am Physicians. 1956;69:56-64 - PubMed
    1. J Clin Microbiol. 1983 Feb;17(2):218-24 - PubMed
    1. J Clin Microbiol. 1982 Mar;15(3):468-74 - PubMed

Publication types

Substances

LinkOut - more resources