The Effect of a Smart Diaper Sensor on Incontinence-Associated Dermatitis Afflicting a Sedentary Patient with Cognitive Impairment
- PMID: 40217977
- PMCID: PMC11989934
- DOI: 10.3390/jcm14072526
The Effect of a Smart Diaper Sensor on Incontinence-Associated Dermatitis Afflicting a Sedentary Patient with Cognitive Impairment
Abstract
Background: Urinary incontinence (UI) is common among hospitalized patients and often leads to complications like incontinence-associated dermatitis (IAD). This risk is heightened among patients with cognitive impairment, as delayed diaper changes can worsen skin conditions. Smart diaper sensors provide a promising solution to these challenges. Methods: A 76-year-old woman with cognitive impairment and gait disturbance presented with itchy erythema and rashes consistent with IAD. Conventional treatments offered partial relief but did not resolve the symptoms. The MONIT smart diaper sensor was used in combination with antifungal ointment. The sensor, attached externally to the diaper, monitored moisture levels in real time and sent alerts to a smartphone via Bluetooth when a diaper change was needed. Results: The MONIT system significantly improved skin condition, as evidenced by reduced scores on the incontinence-associated dermatitis and its severity (IADS) instrument and the perineal assessment tool (PAT). Conclusions: The combined use of the MONIT smart diaper sensor and antifungal treatment effectively managed IAD, reducing its severity and preventing complications. Smart diaper sensors represent valuable tools for improving care for sedentary patients with cognitive impairment, offering innovative support for timely interventions.
Keywords: cognitive deficit; incontinence-associated dermatitis; smart diaper; urinary incontinence.
Conflict of interest statement
The authors have no conflicts of interest to disclose.
Figures



Similar articles
-
A Smart Diaper System Using Bluetooth and Smartphones to Automatically Detect Urination and Volume of Voiding: Prospective Observational Pilot Study in an Acute Care Hospital.J Med Internet Res. 2021 Jul 30;23(7):e29979. doi: 10.2196/29979. J Med Internet Res. 2021. PMID: 34328427 Free PMC article.
-
A Prospective, Multicenter Study to Compare a Disposable, High-fluid Capacity Underpad to Nonpermeable, Disposable, Reusable Containment Products on Incontinence-associated Dermatitis Rates Among Skilled Nursing Facility Residents.Ostomy Wound Manage. 2017 Dec;63(12):22-28. Ostomy Wound Manage. 2017. PMID: 29324430 Clinical Trial.
-
Incidence and risk factors of incontinence-associated dermatitis among patients in the intensive care unit.J Clin Nurs. 2018 Nov;27(21-22):4150-4157. doi: 10.1111/jocn.14594. Epub 2018 Jul 26. J Clin Nurs. 2018. PMID: 29964368
-
Skin assessments and interventions for maintaining skin integrity in nursing practice: An umbrella review.Int J Nurs Stud. 2023 Jul;143:104495. doi: 10.1016/j.ijnurstu.2023.104495. Epub 2023 Apr 5. Int J Nurs Stud. 2023. PMID: 37099847
-
A decade of research on Incontinence-Associated Dermatitis (IAD): Evidence, knowledge gaps and next steps.J Tissue Viability. 2017 Feb;26(1):47-56. doi: 10.1016/j.jtv.2016.02.004. Epub 2016 Feb 21. J Tissue Viability. 2017. PMID: 26949126 Review.
References
Publication types
LinkOut - more resources
Full Text Sources