4D CT acquisition methods and their anticipated effects on image quality in dynamic CT-scanning of the wrist
- PMID: 40251111
- DOI: 10.1016/j.zemedi.2025.03.001
4D CT acquisition methods and their anticipated effects on image quality in dynamic CT-scanning of the wrist
Abstract
Four dimensional computed tomography (4D CT) has shown to be of value in the diagnosis of motion related wrist joint pathologies. 4D CT can be performed with a variety of acquisition methods. However, the usability of 4D CT is affected by motion and image artifacts associated with the specific acquisition method used. In this literature review we inventorize which acquisition methods exist for 4D-CT imaging at different positions of the human body and what the advantages and disadvantages of each method are. Based on this assessment we formulate recommendations for the 4D CT imaging approach for diagnosing motion related wrist pathologies. We also address future perspectives of image acquisition in 4D CT of the wrist joint. We found that scanning in volumetric mode eliminates irregularity artifacts, while reducing acquisition time per frame reduces blurring artifacts. A reduced acquisition time can be achieved with short gantry rotation times, dual source CT and Reconstruction based on Partial Gantry Rotation (RPGR). However, the effect of RPGR on RPGR-specific artifacts and the effect of different acquisition times on apparent object displacements may be investigated in future research.
Keywords: 4D-CT imaging; Wrist joint.
Copyright © 2025 Amsterdam UMC, location AMC. Published by Elsevier GmbH.. All rights reserved.
Conflict of interest statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
System requirements to improve adaptive 4-dimensional computed tomography (4D CT) imaging.Biomed Phys Eng Express. 2022 Oct 18;8(6). doi: 10.1088/2057-1976/ac9849. Biomed Phys Eng Express. 2022. PMID: 36206724
-
Impact of motion velocity on four-dimensional target volumes: a phantom study.Med Phys. 2009 May;36(5):1610-7. doi: 10.1118/1.3110073. Med Phys. 2009. PMID: 19544777
-
Intelligent 4D CT sequence scanning (i4DCT): First scanner prototype implementation and phantom measurements of automated breathing signal-guided 4D CT.Med Phys. 2020 Jun;47(6):2408-2412. doi: 10.1002/mp.14106. Epub 2020 Mar 24. Med Phys. 2020. PMID: 32115724
-
The use of 4D-CT in assessing wrist kinematics and pathology: a narrative view.Bone Joint J. 2019 Nov;101-B(11):1325-1330. doi: 10.1302/0301-620X.101B11.BJJ-2019-0361.R1. Bone Joint J. 2019. PMID: 31674237 Review.
-
Advances in 4D medical imaging and 4D radiation therapy.Technol Cancer Res Treat. 2008 Feb;7(1):67-81. doi: 10.1177/153303460800700109. Technol Cancer Res Treat. 2008. PMID: 18198927 Review.
Publication types
LinkOut - more resources
Full Text Sources