. 2025 Apr 1;96(4):043706.
doi: 10.1063/5.0253841.

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Affiliations

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Jessica Z Dixon et al. Rev Sci Instrum. .

Abstract

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed-most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. We report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

PubMed Disclaimer

Conflict of interest statement

The authors have no conflicts to disclose.

Similar articles

References

    1. Matthäus C., Chernenko T., Newmark J. A., Warner C. M., and Diem M., Biophys. J. 93(2), 668 (2007).10.1529/biophysj.106.102061 - DOI - PMC - PubMed
    1. Uzunbajakava N., Lenferink A., Kraan Y., Volokhina E., Vrensen G., Greve J., and Otto C., Biophys. J. 84, 3968 (2003).10.1016/s0006-3495(03)75124-8 - DOI - PMC - PubMed
    1. Chan J., Fore S., Wachsmann-Hogiu S., and Huser T., Laser Photonics Rev. 2, 325 (2008).10.1002/lpor.200810012 - DOI
    1. Pahlow S., Meisel S., Cialla-May D., Weber K., Rösch P., and Popp J., Adv. Drug Delivery Rev. 89, 105 (2015), part of Special Issue: Pharmaceutical applications of Raman spectroscopy—From diagnosis to therapeutics.10.1016/j.addr.2015.04.006 - DOI - PubMed
    1. Stone N., Kendall C., Smith J., Crow P., and Barr H., Faraday Discuss. 126, 141 (2004).10.1039/b304992b - DOI - PubMed

MeSH terms

LinkOut - more resources