Patient Positioning and Treatment Techniques in Total Skin Irradiation: A Scoping Review

Affiliations
Review

Patient Positioning and Treatment Techniques in Total Skin Irradiation: A Scoping Review

Andrea Lastrucci et al. Cancers (Basel). .

Abstract

Introduction: Total skin irradiation (TSI) is a radiotherapy technique used to treat cutaneous lymphomas, such as mycosis fungoides. A key aspect of the success of the treatment is the correct positioning of the patient, which ensures a homogeneous distribution of radiation over the skin surface, minimizing exposure to the surrounding healthy tissues. Materials and Methods: Following the preferred reporting items for systematic review and meta-analysis (PRISMA) extension for scoping reviews and the Arksey and O'Malley framework, electronic searches of EMBASE, PubMed, SCOPUS, and the Web of Science were conducted to identify original studies detailing positioning techniques for TSI in clinical practice. Results: A total of 44 studies were included, reporting a range of positioning techniques used in TSI. The selected articles were divided into four categories: Stanford, rotational, tomotherapy, and mixed (including studies comparing two or more of the previously mentioned techniques). Articles concerning the Stanford technique were predominant (n = 33; 75.0%), followed by those addressing the rotational technique (n = 5; 11.4%), tomotherapy (n = 3; 6.8%), and mixed (n = 3; 6.8%). Studies on the Stanford technique described both the original method and its modifications, including variations such as the lying position, and analyzed its strengths and limitations. Research on the rotational method examined different device configurations and implementation strategies to optimize dose distribution and treatment efficiency. Mixed articles compared the Stanford and rotational techniques, highlighting their similar dose uniformity while examining differences in treatment efficiency and practical implementation. Conclusions: Despite its widespread use, the Stanford technique is associated with challenges that have led to the exploration of alternative positioning strategies. The rotational technique addresses some of these limitations, while tomotherapy offers advanced immobilization but raises toxicity concerns. Future research should focus on optimizing the balance between efficacy, safety, and practicality of treatment in clinical settings.

Keywords: patient positioning; radiotherapy; total skin electron irradiation.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflicts of interest.

Figures

Figure 1
Figure 1
PRISMA flowchart of study selection.
Figure 2
Figure 2
Retrieved articles are categorized based on the TSI technique used.

Similar articles

References

    1. Hoppe R.T., Fuks Z., Bagshaw M.A. The rationale for curative radiotherapy in mycosis fungoides. Int. J. Radiat. Oncol. Biol. Phys. 1977;2:843–851. doi: 10.1016/0360-3016(77)90182-1. - DOI - PubMed
    1. Jones G.W., Hoppe R.T., Glatstein E. Electron Beam Treatment for Cutaneous T-cell Lymphoma. Hematol./Oncol. Clin. N. Am. 1995;9:1057–1076. doi: 10.1016/S0889-8588(18)30058-3. - DOI - PubMed
    1. Karzmark C.J., Anderson J., Buffa A., Fessenden P., Khan F., Svensson G., Wright K., Almond P., Fraass B., Hogstrom K., et al. Total Skin Electron Therapy: Technique and Dosimetry. American Association of Physicists in Medicine; Alexandria, VA, USA: 1987. Report No. 23. - DOI
    1. Anacak Y., Arican Z., Bar-Deroma R., Tamir A., Kuten A. Total skin electron irradiation: Evaluation of dose uniformity throughout the skin surface. Med. Dosim. 2003;28:31–34. doi: 10.1016/S0958-3947(02)00235-2. - DOI - PubMed
    1. Schiapparelli P., Zefiro D., Massone F., Taccini G. Total skin electron therapy (TSET): A reimplementation using radiochromic films and IAEA TRS-398 code of practice. Med. Phys. 2010;37:3510–3517. doi: 10.1118/1.3442301. - DOI - PubMed

LinkOut - more resources