Abstract
Detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in cryopreserved semen is crucial for screening sperm donors. The evaluation of the limit of detection (LOD) of the APTIMA Combo 2™ kit (Panther, Hologic) was performed on cryopreserved semen samples spiked with CT and NG at concentrations ranging from 1 to 106 IFU/mL or CFU/mL, respectively. The LOD was 102 IFU/mL for CT and 10 CFU/mL for NG in single infection or coinfection. An inhibitory effect of semen on amplification was highlighted. This study confirmed the performance of the APTIMA Combo 2™ kit for screening cryopreserved sperm samples before donation.
Keywords: Chlamydia trachomatis; Neisseria gonorrhoeae; Cryopreserved semen; NAAT.