The influence of induced micromovement upon the healing of experimental tibial fractures
- PMID: 4030869
- DOI: 10.1302/0301-620X.67B4.4030869
The influence of induced micromovement upon the healing of experimental tibial fractures
Abstract
Although it has been well established that fracture healing is influenced by the mechanical environment, the optimal parameters have not yet been established. In two groups of sheep an experimental tibial diaphysial fracture was created, and stabilised using external skeletal fixation. In one group rigid fixation was maintained throughout fracture healing; in the other group controlled axial micromovement, with a loading regime known to be osteogenic in intact bones, was applied for a short period daily. A significant improvement in healing was associated with the application of controlled micromovement. Data from these experiments provide the basis for improving the conditions for fracture healing and may assist in the prevention of delayed union.
Similar articles
-
Controlled mechanical stimulation in the treatment of tibial fractures.Clin Orthop Relat Res. 1989 Apr;(241):36-47. Clin Orthop Relat Res. 1989. PMID: 2924478
-
Strain rate and timing of stimulation in mechanical modulation of fracture healing.Clin Orthop Relat Res. 1998 Oct;(355 Suppl):S105-15. doi: 10.1097/00003086-199810001-00012. Clin Orthop Relat Res. 1998. PMID: 9917631
-
Tibial external fixation, weight bearing, and fracture movement.Clin Orthop Relat Res. 1993 Aug;(293):28-36. Clin Orthop Relat Res. 1993. PMID: 8339493 Clinical Trial.
-
Tibial blood supply in relation to fracture healing.Clin Orthop Relat Res. 1974 Nov-Dec;(105):34-81. Clin Orthop Relat Res. 1974. PMID: 4609655 Review. No abstract available.
-
The effect of rigidity on fracture healing in external fixation.Clin Orthop Relat Res. 1989 Apr;(241):24-35. Clin Orthop Relat Res. 1989. PMID: 2647334 Review.
Cited by
-
Biomechanical Analysis of the Behaviour at the Metaphyseal-Diaphyseal Junction of Complex Tibial Plateau Fractures Using Two Circular Fixator Configurations.Strategies Trauma Limb Reconstr. 2020 Sep-Dec;15(3):138-145. doi: 10.5005/jp-journals-10080-1507. Strategies Trauma Limb Reconstr. 2020. PMID: 34025793 Free PMC article.
-
Elastic stable intramedullary nailing of tibial shaft fractures in children.J Child Orthop. 2011 Aug;5(4):297-304. doi: 10.1007/s11832-011-0343-5. Epub 2011 Jun 2. J Child Orthop. 2011. PMID: 22852036 Free PMC article.
-
Clinical and radiologic outcomes associated with the use of dynamic locking screws (DLS) in distal tibia fractures.Eur J Trauma Emerg Surg. 2016 Jun;42(3):351-6. doi: 10.1007/s00068-015-0543-7. Epub 2015 Jun 11. Eur J Trauma Emerg Surg. 2016. PMID: 26063411
-
Evaluation of a new optical measuring system for experiments on fractured human mandibles: a biomechanical feasibility study in maxillofacial surgery.Clin Oral Investig. 2012 Dec;16(6):1535-42. doi: 10.1007/s00784-011-0659-z. Epub 2011 Dec 24. Clin Oral Investig. 2012. PMID: 22194096
-
Production of VEGF receptor 1 and 2 mRNA and protein during endochondral bone repair is differential and healing phase specific.J Appl Physiol (1985). 2010 Dec;109(6):1930-8. doi: 10.1152/japplphysiol.00839.2010. Epub 2010 Oct 14. J Appl Physiol (1985). 2010. PMID: 20947709 Free PMC article.
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical