Abstract
The Aerotest sampler (Olympic Medical Corp., Seattle, Wash.) is designed to detect bacterial contamination of respirator-generated aerosols in a simple one-step process. The sampler was evaluated by controlled contamination of Bennett AP-5, PR-2, and MA-1 respirators with Escherichia coli, Pseudomonas aeruginosa, and Acinetobacter. Bacteria present as viable 1.4 to 3.5-mum particles in each of 77 aerosols were quantitated by using the Andersen viable-particle sampler, and the results were compared with those of colonies obtained from 10-s or 15-cycle Aerotest samples. All aerosols containing counts greater than expected in hospital air were detected by the Aerotest method. Thirteen of 14 aerosols containing less than 20 bacteria/0.028 m3 showed fewer than 5 colonies, whereas all aerosols containing greater than 1,000 bacteria/0.028 m3 showed at least 40 colonies. Aerosols with intermediate counts fell in between. Under the conditions described here, the Aerotest sampler was able to discriminate between the low levels of bacteria commonly found in hospital air and the bacterial contamination associated with nosocomial pneumonia. The Aerotest sampler provides a practical method for surveillance sampling of respirator nebulizers.
Similar articles
-
Selective nonroutine microbial surveillance of in-use hospital nebulizers by aerosol entrapment and direct sampling analyses of solutions in reservoirs.J Clin Microbiol. 1980 Aug;12(2):199-204. doi: 10.1128/jcm.12.2.199-204.1980. J Clin Microbiol. 1980. PMID: 6785304 Free PMC article.
-
Improved large-volume sampler for the collection of bacterial cells from aerosol.Appl Microbiol. 1975 Mar;29(3):335-9. doi: 10.1128/am.29.3.335-339.1975. Appl Microbiol. 1975. PMID: 803820 Free PMC article.
-
Comparison of Andersen eight-stage and two-stage viable air samplers.Appl Environ Microbiol. 1978 Jan;35(1):208-9. doi: 10.1128/aem.35.1.208-209.1978. Appl Environ Microbiol. 1978. PMID: 341808 Free PMC article.
-
Evaluation of the commercial bacterial air samplers by the new bacterial aerosol generator.Bull Tokyo Med Dent Univ. 1981 Mar;28(1):7-21. Bull Tokyo Med Dent Univ. 1981. PMID: 7011587
-
Bio-aerosols in indoor environment: composition, health effects and analysis.Indian J Med Microbiol. 2008 Oct-Dec;26(4):302-12. doi: 10.4103/0255-0857.43555. Indian J Med Microbiol. 2008. PMID: 18974481 Review.