Parametric analyses of pin-bone stresses in external fracture fixation devices
- PMID: 4032105
- DOI: 10.1002/jor.1100030311
Parametric analyses of pin-bone stresses in external fracture fixation devices
Abstract
Problems occurring in the use of external fixators for bone fractures include pin-bone interface necrosis, infection, and loosening. These may be initiated and enhanced by pin-bone interface stress levels. Based on stress data from finite element method (FEM) models, an analytical "closed-form" model of the local pin-bone configuration in long-bone fracture fixation is developed. This model is relatively simple and useful for routine applications in combination with clinical studies and animal experiments. Although approximate, the most significant stress predictions in the pin-bone structure compare well with more sophisticated FEM analysis results. The analytical model is used for extensive parametric analyses, investigating the effects on the pin-bone interface stress distribution of frame configuration parameters, pin diameter and modulus, bone dimensions, and elastic characteristics. The results indicate that these stresses may reach very high levels under unfavorable circumstances but can be drastically reduced by increasing the bending rigidity of the pin, reducing the side-bar separation and applying full-pin configuration in favor of half-pins.
Similar articles
-
Guidelines for external fixation frame rigidity and stresses.J Orthop Res. 1986;4(1):68-75. doi: 10.1002/jor.1100040108. J Orthop Res. 1986. PMID: 3950810
-
Bone properties affect loosening of half-pin external fixators at the pin-bone interface.Injury. 2012 Oct;43(10):1764-70. doi: 10.1016/j.injury.2012.07.001. Epub 2012 Jul 28. Injury. 2012. PMID: 22841532
-
The effect of rigidity on fracture healing in external fixation.Clin Orthop Relat Res. 1989 Apr;(241):24-35. Clin Orthop Relat Res. 1989. PMID: 2647334 Review.
-
Effects of low-modulus coatings on pin-bone contact stresses in external fixation.J Orthop Res. 1984;2(4):385-92. doi: 10.1002/jor.1100020411. J Orthop Res. 1984. PMID: 6527164
-
Biomechanics and biology of fracture repair under external fixation.Hand Clin. 1993 Nov;9(4):531-42. Hand Clin. 1993. PMID: 8300724 Review.
Cited by
-
Drug loading and release of Tobramycin from hydroxyapatite coated fixation pins.J Mater Sci Mater Med. 2013 Sep;24(9):2265-74. doi: 10.1007/s10856-013-4979-1. Epub 2013 Jun 19. J Mater Sci Mater Med. 2013. PMID: 23779156
-
Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants.Materials (Basel). 2018 Jul 25;11(8):1282. doi: 10.3390/ma11081282. Materials (Basel). 2018. PMID: 30044409 Free PMC article.
-
Analysis of Microbiological Findings on the Surface of External Fixator Pins Comparing Steel Pins with Hydroxyapatite-Coated Pins.Rev Bras Ortop (Sao Paulo). 2025 Jun 23;60(2):1-7. doi: 10.1055/s-0045-1809337. eCollection 2025 Apr. Rev Bras Ortop (Sao Paulo). 2025. PMID: 40551995 Free PMC article.
-
Stability with unilateral external fixation in the tibia.Strategies Trauma Limb Reconstr. 2007 Apr;2(1):13-20. doi: 10.1007/s11751-007-0011-y. Strategies Trauma Limb Reconstr. 2007. PMID: 18427910 Free PMC article.
-
Time-dependent behaviour of bone accentuates loosening in the fixation of fractures using bone-screw systems.Bone Joint Res. 2018 Nov 3;7(10):580-586. doi: 10.1302/2046-3758.710.BJR-2018-0085.R1. eCollection 2018 Oct. Bone Joint Res. 2018. PMID: 30464838 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources