Observational Study
. 2025 May 7;25(1):361.
doi: 10.1186/s12887-025-05728-z.

Clinical value of calibrated abdominal compression plus transthoracic echocardiography to predict fluid responsiveness in critically ill infants: a diagnostic accuracy study

Affiliations
Observational Study

Clinical value of calibrated abdominal compression plus transthoracic echocardiography to predict fluid responsiveness in critically ill infants: a diagnostic accuracy study

Julien Gotchac et al. BMC Pediatr. .

Abstract

Background: Predicting fluid responsiveness is challenging in infants. It is however crucial to avoid unnecessary volume expansion, which can lead to fluid overload. We tested the hypothesis that the stroke volume changes induced by a calibrated abdominal compression (ΔSV-AC) could predict fluid responsiveness in infants without cardiac disease.

Methods: This prospective single center study of diagnostic test accuracy was conducted in a general pediatric intensive care unit (PICU). Children under the age of two with acute circulatory failure and requiring a 10 mL.kg-1 crystalloid volume expansion over 20 min, ventilated or not ventilated, were eligible. Stroke volume was measured by transthoracic echocardiography at baseline, during a gentle calibrated abdominal compression (22 mmHg for 30 s), and after volume expansion. The area under the receiver operating characteristic curve (AUROC) of ΔSV-AC was measured to predict fluid responsiveness, defined as a 15% stroke volume increase after volume expansion.

Results: Twenty-seven cases of volume expansion were analyzed, in 21 patients. Seventeen VE cases were administrated to spontaneously breathing children. Fluid responsiveness was observed in 12 cases. The AUROC of ΔSV-AC was 0.93 (95% confidence interval (95%CI) 0.82-1). The best threshold value for ΔSV-AC was 9.5%. At this threshold value, sensitivity was 92% (95%CI 62-100), specificity was 87% (95%CI 60-98), positive and negative predictive values were 85% (95%CI 60-95) and 93% (95%CI 66-99) respectively.

Conclusions: Echocardiographic assessment of stroke volume changes induced by a calibrated abdominal compression is a promising method to predict fluid responsiveness in infants without cardiac disease hospitalized in PICU.

Trial registration: ClinicalTrials.gov registration number NCT05919719, June 22, 2023, retrospectively registered, https://clinicaltrials.gov/study/NCT05919719 .

Keywords: Circulatory failure; Echocardiography; Fluid responsiveness; Goal-directed fluid management; Volume Expansion.

PubMed Disclaimer

Conflict of interest statement

Declarations. Ethics approval and consent to participate: The study was carried out in accordance with the Good Clinical Practices protocol and Declaration of Helsinki principles. It was approved by our Institutional Review Board (Comité de Protection des Personnes Ouest IV, number 2021-A02876-35, approval date January 11 th 2022) and retrospectively registered on Clinicaltrials.gov (NCT05919719, June 22, 2023). Informed consent was obtained from all parents or legal guardians for minors, before or within 24 h after study procedures. Consent for publication: Not applicable. Competing interests: The authors declare no competing interests.

Figures

Fig. 1
Fig. 1
Study flow chart. Legend: ∆SV-AC, percentage of stroke volume variation between baseline and during a calibrated abdominal compression, VE volume expansion.* For these two subjects, the study procedures were performed but we could not obtain parental informed consent to having their child’s data retained and analysed because of language barrier
Fig. 2
Fig. 2
Receiver operating characteristics (ROC) curve of ∆SV-AC to predict fluid responsiveness. Legend: ∆SV-AC, percentage of stroke volume variation between baseline and during a calibrated abdominal compression

Similar articles

References

    1. Van De Voorde P, Turner NM, Djakow J, De Lucas N, Martinez-Mejias A, Biarent D, et al. European Resuscitation Council Guidelines 2021: Paediatric Life Support. Resuscitation. 2021;161:327–87. - PubMed
    1. Graham CA, Parke TRJ. Critical care in the emergency department: shock and circulatory support. Emerg Med J. 2005;22:17–21. - PMC - PubMed
    1. Weiss SL, Peters MJ, Alhazzani W, Agus MSD, Flori HR, Inwald DP, et al. Surviving sepsis campaign international guidelines for the management of septic shock and sepsis-associated organ dysfunction in children. Intensive Care Med. 2020;46:10–67. - PMC - PubMed
    1. Evans L, Rhodes A, Alhazzani W, Antonelli M, Coopersmith CM, French C, et al. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021. Intensive Care Med. 2021;47:1181–247. - PMC - PubMed
    1. Gan H, Cannesson M, Chandler JR, Ansermino JM. Predicting Fluid Responsiveness in Children: A Systematic Review. Anesth Analg. 2013;117:1380–92. - PubMed

Publication types