Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2025 May 6;10(1):33.
doi: 10.1186/s40834-025-00366-3.

The use of a menstrual cup as a risk factor for displacement of intrauterine devices: a case-control study

Affiliations

The use of a menstrual cup as a risk factor for displacement of intrauterine devices: a case-control study

Juliette Claire et al. Contracept Reprod Med. .

Abstract

Background: Menstrual cups (MC) are being increasingly used for menstruation management as an alternative to tampons and sanitary pads. Intrauterine devices (IUD) are commonly and increasingly used for birth control. Displacement of an IUD from the uterine fundus can reduce its efficiency, potentially leading to unwanted pregnancies. Recently, concerns have been raised regarding a possible increase in the risk of IUD displacement, associated to the use of MC. This study measures the association between MC use and IUD displacement, taking into account the already known risk factors of IUD displacement.

Methods and findings: Women consulting for follow-up of an IUD in two primary care facilities in Paris were enrolled in the study between March 2020 and May 2021. IUD position was assessed by transvaginal ultrasound. Use of MC and exposition to known risk factors for IUD displacement were assessed by a standardized investigator-administered questionnaire. Frequency of MC use was compared between patients with well-positioned IUD and patients with displaced IUD. A linear regression model looked for an independent association between MC use and IUD displacement, with respect to known risk factors for IUD displacement. 747 patients were included, out of which 6.8% had a displaced IUD. MC use was reported by 17.0% of patients with a well-positioned IUD versus. 41.2% of patients with a displaced IUD. After adjustment for known risk factors of IUD displacement, MC use appeared to be significantly and independently associated with IUD displacement (aOR [95CI]: 3.09 [1.56-6.05]).

Conclusions: The use of a menstrual cup seems to be an independent risk factor for intrauterine device displacement.

Clinical trial registration: NCT04782583.

Keywords: Case-control study; General practice; Intrauterine device; Menstrual cup; Transvaginal ultrasound.

PubMed Disclaimer

Conflict of interest statement

Declarations. Ethical approval and consent to participate: All participants signed an informed consent for study participation. The study obtained approval from the “Comité de Protection des Personnes Sud Méditerranée V” in February 2020 (IDRCB: 2019-A02870-57). Consent for publication: Not applicable. Competing interests: The authors declare no competing interests.

Figures

Fig. 1
Fig. 1
IUD follow-up consultations inclusion flowchart

References

    1. Rahib D, Le Guen M, Lydié N. [Four years after the pill crisis the evolution of contraceptive methods continues]. Baromètre Santé Contraception [Internet]. 25 sept 2017 [cité 20 sept 2021]; https://www.santepubliquefrance.fr/determinants-de-sante/sante-sexuelle/...
    1. Thomé C. Après La pilule. Le Choix contraceptif des jeunes femmes à L’épreuve du rejet des hormones [After the pill. Young women’s contraceptive choices in the age of hormone rejection]. Sante Publique. 2024;36(1):87–96. 10.3917/spub.241.0087. French. PMID: 38580471. - PubMed
    1. Hédon B, Chabbert-Buffet N, Marret H. [Contraception: recommendations for clinical practice]. In 2018. pp. 755–1088. http://www.cngof.fr/pratiques-cliniques/recommandations-pour-la-pratique...
    1. Jatlaoui TC, Riley HEM, Curtis KM. The safety of intrauterine devices among young women: a systematic review. Contracept Janv. 2017;95(1):17–39. - PMC - PubMed
    1. Madden T, McNicholas C, Zhao Q, Secura GM, Eisenberg DL, Peipert JF. Association of age and parity with intrauterine device expulsion. Obstet Gynecol Oct. 2014;124(4):718–26. - PMC - PubMed

Associated data

LinkOut - more resources