Electroanatomic mapping of the right atrial breakout site during retrograde Bachmann bundle pacing in 15 patients in sinus rhythm undergoing pulmonary vein isolation provided the anatomic localization of the putative lead insertion target for Bachmann bundle pacing. In all patients the target area could be mapped to the inferoseptal superior vena cava, with some variation in the earliest breakout site in the anteroposterior plane. Microstructural correlation reveals that the Bachmann bundle functions as an atrial conduction pathway supported by anatomic features to provide interatrial synchrony.
Keywords: Alternate site pacing; Atrial activation; Atrial resynchronization; Bachmann bundle electrogram; Bachmann bundle pacing; Conduction system pacing.
Copyright © 2025 Heart Rhythm Society. All rights reserved.
Conflict of interest statement
Disclosures Drs Lustgarten, Habel, Iaizzo, and Meyer have received research funding from Medtronic. Dr Meyer has received research funding from the Engdahl Family Foundation. Dr Infeld has received speaker fees from Medtronic.