. 2025 Mar 18;7(1):71-75.
doi: 10.1089/bioe.2024.0027. eCollection 2025 Mar.

Pulse Lavage and Electrical Fields to Remove Biofilms from Cobalt-Chrome Surfaces: An In Vitro Study

Affiliations

Pulse Lavage and Electrical Fields to Remove Biofilms from Cobalt-Chrome Surfaces: An In Vitro Study

Martí Bernaus et al. Bioelectricity. .

Abstract

Introduction: With the increased use of metallic devices in medical disciplines, the number of potential complications has also risen. Orthopedic implant-related infections are a serious complication often requiring a combination of surgical and prolonged antibiotic treatment. Biofilms play an important role in implant-related infections, and many different strategies have been studied to remove it. The purpose of our study was to evaluate the effectiveness of electrical fields and pulse lavage to remove S. epidermidis biofilm from metallic surfaces used in joint arthroplasty.

Methods: We compared five different models and combination treatments in an in vitro scenario to remove the biofilm. Five different models were compared with a model without treatment (control): (a) low-pressure pulse lavage, (b) high-pressure pulse lavage, (c) pulsed electrical fields, (d) low-pressure pulse lavage in combination with pulsed electrical fields, and (e) high-pressure pulse lavage in combination with pulsed electrical fields. Electrical fields were applied using 25 pulses at 15 V. Each pulse lasted 0.1 s and was applied every 0.5 s for a total exposure time of 12.5 s. The exposure time for irrigation was set at 25 s.

Results: The most effective model for removing biofilm from cobalt-chrome surfaces was a combination of high-pressure pulse lavage and electrical fields.

Conclusion: Our study results suggest the use of pulsed electrical fields is effective at removing biofilm and that our tested conditions could be translated to a clinical scenario involving infected medical devices.

Keywords: biofilm; electrical fields; implant infection; pulse lavage.

PubMed Disclaimer

Similar articles

References

    1. Trebse R, Roskar S. Evaluation and interpretation of prosthetic joint infection diagnostic investigations. Int Orthop 2021;45(4):847–855; doi: 10.1007/s00264-021-04958-x - DOI - PubMed
    1. Wi YM, Patel R. Understanding biofilms and novel approaches to the diagnosis, prevention, and treatment of medical device-associated infections. Infect Dis Clin North Am 2018;32(4):915–929; doi: 10.1016/j.idc.2018.06.009 - DOI - PMC - PubMed
    1. Kunutsor SK, Beswick AD, Whitehouse MR, et al. . Debridement, antibiotics and implant retention for periprosthetic joint infections: A systematic review and meta-analysis of treatment outcomes. J Infect 2018;77(6):479–488; doi: 10.1016/j.jinf.2018.08.017 - DOI - PubMed
    1. Gbejuade HO, Lovering AM, Webb JC. The role of microbial biofilms in prosthetic joint infections. Acta Orthop 2015;86(2):147–158; doi: 10.3109/17453674.2014.966290 - DOI - PMC - PubMed
    1. Knecht CS, Moley JP, McGrath MS, et al. . Antibiotic loaded calcium sulfate bead and pulse lavage eradicates biofilms on metal implant materials in vitro. J Orthop Res 2018;36(9):2349–2354; doi: 10.1002/jor.23903 - DOI - PubMed