Randomized Controlled Trial
. 2025 Jun;10(6):e8-e16.
doi: 10.1016/S2468-1253(25)00136-0.

Endoscopic ultrasonography-guided gastroenterostomy versus uncovered duodenal metal stenting for unresectable malignant gastric outlet obstruction (DRA-GOO): a multicentre randomised controlled trial

Affiliations
Randomized Controlled Trial

Endoscopic ultrasonography-guided gastroenterostomy versus uncovered duodenal metal stenting for unresectable malignant gastric outlet obstruction (DRA-GOO): a multicentre randomised controlled trial

Anthony Yuen Bun Teoh et al. Lancet Gastroenterol Hepatol. 2025 Jun.

Abstract

Background: Endoscopic ultrasonography-guided gastroenterostomy (EUS-GE) is a novel endoscopic method to palliate malignant gastric outlet obstruction. We aimed to assess whether the use of EUS-GE with a double balloon occluder for malignant gastric outlet obstruction could reduce the need for reintervention within 6 months compared with conventional duodenal stenting.

Methods: The was an international, multicentre, randomised, controlled trial conducted at seven sites in Hong Kong, Belgium, Brazil, India, Italy, and Spain. Consecutive patients (aged ≥18 years) with malignant gastric outlet obstruction due to unresectable primary gastroduodenal or pancreatobiliary malignancies, a gastric outlet obstruction score (GOOS) of 0 (indicating an inability to intake food or liquids orally), and an Eastern Cooperative Oncology Group performance status score of 3 or lower were included and randomly allocated (1:1) to receive either EUS-GE or duodenal stenting. The primary outcome was the 6-month reintervention rate, defined as the percentage of patients requiring additional endoscopic intervention due to stent dysfunction (ie, restenosis of the stent due to tumour ingrowth, tumour overgrowth, or food residue; stent migration; or stent fracture) within 6 months, analysed in the intention-to-treat population. Prespecified secondary outcomes were technical success (successful placement of a stent), clinical success (1-point improvement in gastric outlet obstruction score [GOOS] within 3 days), adverse events within 30 days, death within 30 days, duration of stent patency, GOOS at 1 month, and quality-of-life scores. This study is registered with ClinicalTrials.gov (NCT03823690) and is completed.

Findings: Between Dec 1, 2020, and Feb 28, 2022, 185 patients were screened and 97 (46 men and 51 women) were recruited and randomly allocated (48 to the EUS-GE group and 49 to the duodenal stent group). Mean age was 69·5 years (SD 12·6) in the EUS-GE group and 64·8 years (13·0) in the duodenal stent group. All randomly allocated patients completed follow-up and were analysed. Reintervention within 6 months was required in two (4%) patients in the EUS-GE group and 14 (29%) in the duodenal stent group [p=0·0020; risk ratio 0·15 [95% CI 0·04-0·61]). No significant difference in duration of stent patency was noted between groups. 1-month GOOS was significantly better in the EUS-GE group (mean 2·41 [SD 0·7]) than the duodenal stent group (1·91 [0·9], p=0·012). There were no statistically significant differences between the EUS-GE and duodenal stent groups in death within 30 days (ten [21%] vs six [12%] patients, respectively, p=0·286), technical success, clinical success, or quality-of-life scores at 1 month. Adverse events occurred 11 (23%) patients in the EUS-GE group and 12 (24%) in the duodenal stent group within 30 days (p=1·00); three cases of pneumonia (two in the EUS-GE group and one in the duodenal stent group) were considered to be procedure related.

Interpretation: In patients with malignant gastric outlet obstruction, EUS-GE can reduce the frequency of reintervention and result in better patient-reported eating habits compared with duodenal stenting although there was no significant difference in duration of stent patency or overall survival between the two approaches. EUS-GE could be used preferentially over duodenal stending when expertise and required devices are available.

Funding: Research Grants Council (Hong Kong Special Administrative Region, China) and Sociedad Española de Endoscopia Digestiva.

PubMed Disclaimer

Conflict of interest statement

Declaration of interests AYBT is a consultant for Boston Scientific, Cook, Taewoong, Microtech, and M I Tech Medical Corporations. RK is a consultant for Boston Scientific, Olympus, BCM, Omega Medical Imaging, Apollo Endosurgery, Ambu, M I Tech, and Tigen Pharma. MP-M is a consultant for Boston Scientific, Olympus, Medtronic, and M I Tech Medical Corporations. All other authors declare no competing interests.