Validity and reliability of Gripwise digital dynamometer in the assessment of handgrip strength in older adults

Affiliations

Validity and reliability of Gripwise digital dynamometer in the assessment of handgrip strength in older adults

Gabriela Benatti de Oliveira et al. Front Aging. .

Abstract

Introduction: With the advancement of studies on the importance of sarcopenia in the aging process, new technologies have been developed to assess muscle mass and function. However, most research on portable devices has not considered a wide range of ages and clinical conditions. This study aimed to evaluate the reliability of the Gripwise digital dynamometer in measuring handgrip strength in older Brazilian adults, comparing its performance with the widely used Saehan device.

Methods: A cross-sectional study was conducted with 149 participants (32 men and 117 women), with an average age of 69.5 years. Handgrip strength was measured using both the Gripwise and Saehan dynamometers. Reliability was assessed using the intraclass correlation coefficient (ICC). Analyses considered three handgrip strength measurements from both devices, as well as the highest value obtained. The classification of dynapenia (low muscle strength) was compared using different cutoff points proposed by Villain et al. (2023), Spexoto et al. (2022), and Cruz-Jentoft et al. (2019).

Results: Both dynamometers demonstrated excellent reliability, with ICC values above 0.90. However, significant differences in mean handgrip strength values were observed between the devices (approximately 3.5-four kgf). These variations impacted the classification of dynapenia, with the Gripwise identifying more cases of low muscle strength compared to Saehan.

Conclusion: The lower values reported by the Gripwise may impact clinical decision-making in two ways. On one hand, lower values may lead to earlier detection of muscle weakness, allowing for quicker intervention in individuals with strength below typical thresholds. However, this could also result in an overestimation of the prevalence of dynapenia if the values do not accurately reflect true muscle strength, which could lead to unnecessary interventions. Therefore, it is crucial to consider the need for adjustments in the cutoff points when using Gripwise. These findings highlight the need to revise cutoff points for dynapenia classification, considering device variations and model differences in older age groups.

Keywords: aging; dynamometer; dynapenia; handgrip strength; reliability.

PubMed Disclaimer

Conflict of interest statement

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The handling editor CC is currently organizing a Research Topic with the author LPC.

Figures

FIGURE 1
FIGURE 1
Bland-altman plot: Difference in maximum measured HandGrip strength (kgf) between dynamometers (saehan–gripwise).

Similar articles

References

    1. Benatti de Oliveira G., Vilar Fernandes L., Summer Chen X., Drumond Andrade F. C., Scarlazzari Costa L., Junqueira Vasques A. C., et al. (2024). Intra- and inter-rater reliability of muscle and fat thickness measurements obtained using portable ultrasonography in older adults. Clin. Nutr. ESPEN 60, 65–72. 10.1016/j.clnesp.2024.01.005 - DOI - PubMed
    1. Benz E., Pinel A., Guillet C., Capel F., Pereira B., De A. M., et al. (2024). Sarcopenia and sarcopenic obesity and mortality among older people. JAMA Netw. Open 7 (3), E243604. 10.1001/jamanetworkopen.2024.3604 - DOI - PMC - PubMed
    1. Bloom M., Preston E., Salmon R., Ada L., Flynn A. (2023). Reliability of hand-held dynamometry for measuring force production in people with Parkinson’s disease. Internet J. Allied Heal Sci. Pract. 21 (1), 1–7. 10.46743/1540-580X/2023.2176 - DOI
    1. Chandler A. J., Dona S. T., Cintineo H. P., McFadden B. A., Sanders D. J., Monaco R., et al. (2020). Intra- and inter-rater reliability of assessing body composition using B-mode ultrasound in conjunction with. Artif. Intell. Softw. 3 (2). Available online at: https://www.journalofexerciseandnutrition.com/index.php/JEN/article/view/60.
    1. Chen X., Liu G., Li S., Lin X., Han Z., Hu X., et al. (2023). Handgrip measurement method affects asymmetry but not weakness identification in community-dwelling older adults. J. Am. Med. Dir. Assoc. 24 (3), 284–291.e3. 10.1016/j.jamda.2022.10.013 - DOI - PubMed

LinkOut - more resources