Monte Carlo calculation of119Sb microscale absorbed dose using cascaded and averaged Auger electron spectra
- PMID: 40359966
- DOI: 10.1088/1361-6560/add851
Monte Carlo calculation of119Sb microscale absorbed dose using cascaded and averaged Auger electron spectra
Erratum in
-
Corrigendum: Monte Carlo calculation of119Sb microscale absorbed dose using cascaded and averaged Auger electron spectra (2025Phys. Med. Biol. 70 115022).Phys Med Biol. 2025 Oct 16;70(20). doi: 10.1088/1361-6560/ae0f6f. Phys Med Biol. 2025. PMID: 41099459
Abstract
Radionuclides decaying by electron capture or internal transition produce a large number of Auger electrons in a cascade that follows their radioactive decay. A shortlist of the most potent Auger electron-emitters has appeared in the literature including103mRh,103Pd,111In,119Sb,123I,125I,165Er, and197Hg. Among them,119Sbhas been identified as the most potent for targeting micrometastases, yielding several tens of Auger electrons per decay with energies from a few eV up to 30 keV. In this paper, we recalculate Auger, Coster-Kronig, and super Coster-Kronig yields and transition probabilities as subshell-normalized relative transition probabilities and develop a new method to create radionuclide sources in TOPAS Monte Carlo, the code for which has been made publicly available. We then apply our method to encode the Auger electron spectra of119Sbfrom MIRD RADTABS and EADL into TOPAS and calculate the absorbed dose to water volumes of radius10nmup to10μm, finding that the averaged MIRD Auger electron spectrum underestimates the absorbed dose by a factor of 20 to 50 on this scale. We show that this result is not isolated to119Sband conclude that either the cascaded MIRD or EADL spectrum should be used for accurate microscale dosimetry. We compare with results obtained using the built-in Geant4 Atomic Relaxation for119Sbin TOPAS and find an unexpected continuum of low-energy electrons but no excess absorbed dose relative to either MIRD or EADL. We show that119Sbdoes not produce more absorbed dose in microscale volumes than103mRh,103Pd,111In,123I,125I,165Er, or197Hg, warranting future microdosimetry calculations of RBE and DNA damage to understand whether119Sbis the most potent Auger electron-emitter, as claimed in the literature.
Keywords: Auger electrons; Monte Carlo; antimony-119; indium-111; iodine-125; mercury-197; targeted radionuclide therapy.
Creative Commons Attribution license.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources