. 2025 Apr 28;14(9):3040.
doi: 10.3390/jcm14093040.

A Comparative Evaluation of the Primary and Secondary Stability of Dental Implants with Progressive and Conventional Thread Designs: A Prospective Non-Interventional Study of 100 Implants in 62 Patients

Affiliations

A Comparative Evaluation of the Primary and Secondary Stability of Dental Implants with Progressive and Conventional Thread Designs: A Prospective Non-Interventional Study of 100 Implants in 62 Patients

Daniel Seidel et al. J Clin Med. .

Abstract

Objectives: We wished to compare the primary and secondary stability of dental implants with a progressive design (PL) versus a conventional thread design (SL) across various clinical settings. Methods: A total of 100 implants (50 PL and 50 SL) were placed in 62 patients. The stability of the implants was assessed using a resonance frequency analysis (RFA) at the time of placement (T1) and 20 weeks postoperatively before prosthetic loading (T2). Bone density was measured in Hounsfield units (HU) using cone-beam computed tomography (CBCT). The ISQ values were recorded for each group and anatomical region, including both inter- and intragroup comparisons over time. Results: Both implant designs showed a significant increase in stability during the healing period. At T1, the ISQ values were comparable between groups (SL: 71.3 ± 8.6; PL: 71.1 ± 8.7). At T2, the ISQ values increased significantly in both groups (SL and PL: p < 0.01), with no statistically significant difference in the degree of the gain in stability. The ISQ values were generally lower in the maxilla compared to those in the mandible. In the posterior mandible, the SL implants demonstrated a greater increase in stability compared to that with the PL implants. A strong positive correlation between the HU and ISQ values was observed for both groups (SL: r = 0.95; PL: r = 1.00), without reaching statistical significance. Conclusions: While the progressive thread design aims to enhance the primary stability, it did not outperform the conventional design in this study. Both implant types proved effective in achieving stable and predictable clinical outcomes.

Keywords: implant macro-design; implant stability quotient (ISQ); primary stability; resonance frequency analysis (RFA); secondary stability; thread design.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflicts of interest.

Figures

Figure 1
Figure 1
A depiction of the two implant designs assessed. Left: The SL implant with a slight taper and a single thread with a 0.7 mm uniform pitch. Right: The PL implant with a parallel-walled, apically tapered shape, featuring a 1.0 mm uniform thread pitch and crestal micro-threads at the top.
Figure 2
Figure 2
Distribution and locations of Screw-Line (SL, blue) and Progressive-Line implants (PL, green).
Figure 3
Figure 3
The mean implant stability quotient (ISQ) values in the maxilla and mandible at implant insertion (T1) for Screw-Line (SL, blue) and Progressive-Line (PL, green) implants. The ISQ increase observed until prosthetic loading (T2) is represented in gray.
Figure 4
Figure 4
A Boxplot is showing total implant stability quotient (ISQ) values at implant insertion (T1) and at prosthetic loading (T2) for Screw-Line (SL) and Progressive-Line (PL) implants. Separate ISQ increases over time are displayed in gray for SL implants and in green for PL implants.
Figure 5
Figure 5
The mean implant stability quotient (ISQ) values in the anterior and posterior maxilla at implant insertion (T1) for Screw-Line (SL, blue) and Progressive-Line (PL, green) implants. The ISQ increase observed until prosthetic loading (T2) is represented in gray. The x-axis represents the location and time point (anterior–T1/T2, posterior–T1/T2), while the y-axis shows the ISQ values.
Figure 6
Figure 6
The mean implant stability (ISQ) values in the anterior and posterior mandible at implant insertion (T1) for Screw-Line (SL, blue) and Progressive-Line (PL, green) implants. The ISQ increase observed until prosthetic loading (T2) is represented in gray.

Similar articles

References

    1. Moraschini V., Poubel L.A., Ferreira V.F., Barboza Edos S. Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years: A systematic review. Int. J. Oral Maxillofac. Surg. 2015;44:377–388. doi: 10.1016/j.ijom.2014.10.023. - DOI - PubMed
    1. Tey V.H.S., Phillips R., Tan K. Five-year retrospective study on success, survival and incidence of complications of single crowns supported by dental implants. Clin. Oral Implants Res. 2017;28:620–625. doi: 10.1111/clr.12843. - DOI - PubMed
    1. Rosa C., Bento V., Duarte N., Sayeg J., Santos T., Pellizzer E. Do dental implants installed in different types of bone (I, II, III, IV) have different success rates? A systematic review and meta-analysis. Saudi Dent. J. 2024;36:428–442. doi: 10.1016/j.sdentj.2023.12.007. - DOI - PMC - PubMed
    1. Fouda A.A.H. The impact of the alveolar bone sites on early implant failure: A systematic review with meta-analysis. J. Korean Assoc. Oral Maxillofac. Surg. 2020;46:162–173. doi: 10.5125/jkaoms.2020.46.3.162. - DOI - PMC - PubMed
    1. Raghavendra S., Wood M.C., Taylor T.D. Early wound healing around endosseous implants: A review of the literature. Int. J. Oral Maxillofac. Implants. 2005;20:425–431. - PubMed