Clinical and functional outcomes of plate and screw osteosynthesis in mason type III and IV radial head fractures in the absence of a radial head prosthesis
- PMID: 40372555
- DOI: 10.1007/s00590-025-04319-z
Clinical and functional outcomes of plate and screw osteosynthesis in mason type III and IV radial head fractures in the absence of a radial head prosthesis
Abstract
Introduction: Radial head and neck fractures represent a significant portion of elbow fractures in adults, particularly affecting younger patients due to falls onto outstretched hands. Surgical treatment is often necessary for displaced and comminuted fractures, especially those with associated ligamentous injuries. This study evaluates the long-term clinical, functional, and radiological outcomes of patients with Mason type III and IV radial head fractures managed through open reduction and internal fixation using plate and screw osteosynthesis, due to the unavailability of radial head prostheses.
Material and method: We retrospectively analyzed 28 patients with Mason type III or IV radial head fractures treated with open reduction and internal fixation (ORIF) between 2020 and 2024. Clinical assessments included the visual analog scale (VAS) for pain, Mayo Elbow Performance (MEP) Score, and Quick Disabilities of the Arm, Shoulder and Hand (Quick-DASH) score, as well as measurements of elbow flexion, extension, supination, and pronation. Radiographic evaluations assessed fracture union, loss of reduction, implant breakage or loosening, avascular necrosis, radiographic arthritis, and heterotopic ossification.
Results: At a mean follow-up of 29.1 ± 20.1 months in 28 patients (16 M/12F; mean age 48.5 ± 12.6 years), mean elbow flexion was 120.4 ± 14.7, extension loss 10 ± 5.9, supination 68.9 ± 8.8°, and pronation 62.8 ± 7.1°, with mean VAS 2.3 ± 1.1, MEP Score 83.0 ± 8.9, and Quick-DASH 12.8 ± 7.6. Complete fracture union was achieved in 25 cases, partial union in 2, and asymptomatic nonunion in 1. Complications occurred in three patients (10%), including implant loosening, loss of reduction, heterotopic ossification, and avascular necrosis; two patients showed post-traumatic degenerative changes. One patient required K-wire removal due to migration and another underwent revision fixation with iliac crest bone graft for screw loosening/nonunion. No cases needed open arthrolysis or secondary radial head resection.
Conclusion: While osteosynthesis is effective in managing Mason type III and IV radial head fractures, having a radial head prosthesis available in the operating room can provide flexibility, especially in comminuted fractures, and potentially reduce the need for revision surgeries. These findings underscore the importance of adaptable surgical planning to improve outcomes in complex radial head fractures.
Keywords: Elbow fractures; Osteosynthesis; Radial head fractures; Radial head prothesis.
© 2025. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.
Conflict of interest statement
Declarations. Conflict of interest: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Similar articles
-
[Locking plate osteosynthesis of the radial head fractures : clinical and radiological results].Unfallchirurg. 2015 Nov;118(11):949-56. doi: 10.1007/s00113-014-2562-y. Unfallchirurg. 2015. PMID: 25432670 Clinical Trial. German.
-
Minimum 10-year follow-up after open reduction and internal fixation of radial head fractures Mason type II and III.J Shoulder Elbow Surg. 2025 Feb;34(2):531-542. doi: 10.1016/j.jse.2024.07.022. Epub 2024 Sep 1. J Shoulder Elbow Surg. 2025. PMID: 39222742
-
Open reduction and internal fixation of Mason type III radial head fractures with and without an associated elbow dislocation.J Hand Surg Am. 2007 Dec;32(10):1560-8. doi: 10.1016/j.jhsa.2007.09.016. J Hand Surg Am. 2007. PMID: 18070645
-
Comminuted fractures of the radial head: comparison of resection and internal fixation. Surgical technique.J Bone Joint Surg Am. 2006 Mar;88 Suppl 1 Pt 1:11-23. doi: 10.2106/JBJS.E.00841. J Bone Joint Surg Am. 2006. PMID: 16510796 Review.
-
Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.J Invest Surg. 2018 Jun;31(3):178-184. doi: 10.1080/08941939.2017.1299262. Epub 2017 Sep 13. J Invest Surg. 2018. PMID: 28901795
References
-
- Lipman MD, Gause TM, Teran VA, Chhabra AB, and Deal DN (2018) Radial head fracture fixation using tripod technique with headless compression screws. https://doi.org/10.1016/j.jhsa.2018.03.009 .
-
- Jordan RW and DR. Jones A (2017) Radial Head Fractures. Open Orthop J, vol. 11, no. 1, pp. 1405–1416, https://doi.org/10.2174/1874325001711011405 .
-
- Wu PH, Shen L, Chee YH (2016) Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures. J Orthop Surg. https://doi.org/10.1177/230949901602400114 - DOI
-
- Kaas L, Turkenburg JL, Van Riet RP, Vroemen JPAM, Eygendaal D (2010) Magnetic resonance imaging findings in 46 elbows with a radial head fracture. Acta Orthop. https://doi.org/10.3109/17453674.2010.483988 - DOI - PubMed - PMC
-
- Al-Burdeni S, Abuodeh Y, Ibrahim T, Ahmed G (2015) Open reduction and internal fixation versus radial head arthroplasty in the treatment of adult closed comminuted radial head fractures (modified Mason type III and IV). Int Orthop. https://doi.org/10.1007/s00264-015-2755-1 - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Medical